<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aichi Tokei &#8211; Hà Sơn</title>
	<atom:link href="https://congcusanxuat.vn/danh-muc-san-pham/nha-san-xuat/aichi-tokei/feed/" rel="self" type="application/rss+xml" />
	<link>https://congcusanxuat.vn</link>
	<description>Công cụ sản xuất</description>
	<lastBuildDate>Tue, 07 Sep 2021 07:09:56 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.8</generator>

<image>
	<url>https://congcusanxuat.vn/wp-content/uploads/2020/03/cropped-logo2-2-32x32.gif</url>
	<title>Aichi Tokei &#8211; Hà Sơn</title>
	<link>https://congcusanxuat.vn</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Đồng hồ đo lưu lượng gas Aichi Tokei TBX30/L3</title>
		<link>https://congcusanxuat.vn/san-pham/dong-ho-do-luu-luong-gas-aichi-tokei-tbx30-l3/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 07:09:55 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12450</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/turbine-gas-meters-for-flow-management/">Đồng hồ đo lưu lượng gas Aichi Tokei TBX30/L3</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Features</h1>
<p class="size15">Turbine meters in the TBZ and TBX series were developed for controlling the gas consumption of each piece of equipment such as compact boilers and various industrial furnaces.</p>
<p class="size15">The products realize a smart design with a lightweight and compact body and support a wide range of measurement including maximum working pressure and maximum measuring flow rate.</p>
<p class="size15">Furthermore, the built-in 2-system pulse transmitters enable you to establish a remote meter reading system and an energy control system.</p>
<p class="size15">The TBZ series even corrects temperature and pressure to allow you to read gas consumption in the standard conversion condition.</p>
<p class="size15 mb10">The external power supply model TBX-D has been newly added to the lineup of the TBX series. You can choose the model that would best suit your applications for better usability.</p>
<p class="size13 mb35">Note) TBX30, TBX100, and TBX100F are CE compliant. (Collaborative development product with Tokyo Gas Co., Ltd.)</p>
<p class="size15 mb35"><img fetchpriority="high" decoding="async" class="size-full wp-image-941" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/i_feature_2.jpg" alt="i_feature_2" width="290" height="200" /><br />
・The maximum working pressure covers low, medium and high pressures.<br />
・Free installation positions.<br />
・Equipped with two systems of pulse transmitter.<br />
・Supports a variety of gases and a wider range of applications.<br />
・LCD display that gives you more information.<br />
・Corrects temperature and pressure. (TBZ series).<br />
・Non-stop operation for seven years. (For the battery specifications)</p>
<p class="size15 bold">Application examples</p>
<p class="size15 mb35">・Manage and control gas flows of burning equipment such as burners, boilers and furnaces.<br />
・Manage and control flows of hot and chilled water generators in compact to medium sizes.<br />
・Manage and control flows of gas refrigerators.<br />
・Manage and control gas flows as a part of plant instrumentation.<br />
・For various experimental devices relating to gas flows.</p>
<p class="size15 bold">System drawing</p>
<p><img decoding="async" class="alignnone size-full wp-image-944" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png" sizes="(max-width: 931px) 100vw, 931px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png 931w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_-300x104.png 300w" alt="system_" width="931" height="324" /></p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p class="size15 bold">The model with the correcting function (TBZ series)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th colspan="2">Basic model</th>
<th colspan="3">TBZ60</th>
<th colspan="3">TBZ150</th>
<th colspan="3">TBZ300</th>
</tr>
<tr>
<th rowspan="2">Model name</th>
<th>Flow rate correcting model (with the functions of temperature and pressure correction)</th>
<td>–</td>
<td>TBZ 60-3.5</td>
<td>TBZ 60-9.9</td>
<td>–</td>
<td>TBZ 150-3.5</td>
<td>TBZ 150-9.9</td>
<td>–</td>
<td>TBZ 300-3.5</td>
<td>TBZ 300-9.9</td>
</tr>
<tr>
<th>Actual flow rate model (without the functions of temperature and pressure)</th>
<td>TBZ 60-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 150-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 300-0</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td colspan="3">6～60m3/h</td>
<td colspan="3">12.5～150m3/h</td>
<td colspan="3">30～300m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="9">±1%FS and ±3%RS</td>
</tr>
<tr>
<th>Operator parts and temperature and pressure correction parts</th>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
</tr>
<tr>
<th rowspan="7">Display</th>
<th>Corrected gross accumulated flow rate (Only for the corrected flow rate model)</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Trip flow rate *2</th>
<td colspan="8">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>Large LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Corrected instantaneous flow rate (Only for the flow rate correction model)</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Temperature (Only for the models with temperature and pressure correction)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th>Pressure (Only for the corrected flow rate model)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td colspan="3">JIS 10K 40A flange</td>
<td colspan="3">JIS 10K 50A flange</td>
<td colspan="3">JIS 10K 80A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="9">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="9">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="9">Horizontal and Vertical (Display supports both directions.)</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="9">Indoor and outdoor * 5</td>
</tr>
<tr>
<th colspan="2">Case structure</th>
<td colspan="9">Drip-proof structure, IPX 2 equivalent (JIS-CO920)</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="9">Built-in lithium battery</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="9">Two systems of open collectors (corrected pulse and unadjusted pulse * 6)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 7</th>
<td colspan="9">100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="9">Main piping: Stainless steel; Flange: Steel; Display: Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Temperature sensor</th>
<td colspan="9">Platinum resistance temperature detector thermal sensor: JIS A class</td>
</tr>
<tr>
<th colspan="2">Pressure sensor</th>
<td colspan="9">Semiconductor type pressure sensor (High precision)</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td colspan="3">5.3kg</td>
<td colspan="3">6.0kg</td>
<td colspan="3">9.4kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13 mb35">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate for the actual flow rate model (without temperature and pressure correction).. *3. Under the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C.. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5. Avoid direct contact of water onto the meter if the meter is installed outdoors.. *6: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *7. TBZ uses corrected pulse while TBX uses unit pulse.</p>
<p class="size15 bold">Specifications of actual flow display model (TBX series)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th colspan="2">Model type</th>
<th>TBX30</th>
<th>TBX100</th>
<th>TBX100F</th>
<th>TBX150F</th>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td>4～30m3/h</td>
<td>10～100m3/h</td>
<td>10～100m3/h</td>
<td>12.5～150m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td colspan="4">100kPa</td>
</tr>
<tr>
<th>Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="4">±1%FS</td>
</tr>
<tr>
<th rowspan="3">Display</th>
<th>Trip flow rate *2</th>
<td colspan="3">Large LCD in 6 digits with minimum reading of 10 L</td>
<td>LCD in 6 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="3">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td>LCD in 3 digits with minimum reading of 0.1m3/h</td>
<td colspan="2">LCD in 4 digits with minimum reading of 0.1m3/h</td>
<td>LCD in 3 digits with minimum reading of 1m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td>Rc1 1/2、Rc1 1/4</td>
<td>Rc2</td>
<td colspan="2">JIS 10K 50A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="4">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="4">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="4">Horizontal and vertical</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="4">Indoor</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="4">Built-in lithium battery or external power supply (24 VDC)</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="4">Two systems of open-drain output (unit pulse and high-density pulse * 5)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 6</th>
<td colspan="4">TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="2">Aluminum alloy</td>
<td>Cast iron</td>
<td>Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td>0.8kg</td>
<td>1.8kg</td>
<td>7.0kg</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate. for the actual flow rate model (without temperature and pressure correction).. *3. In the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *6. TBZ uses a corrected pulse while TBX uses a unit pulse.</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<p class="size15 bold">Dimensions of the turbine meter TBZ</p>
<div class="mb10"><img decoding="async" class="alignnone size-full wp-image-945" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbz.gif" alt="size_image_tbz" width="530" height="170" /></div>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Model</th>
<th rowspan="2">L</th>
<th rowspan="2">H</th>
<th rowspan="2">W</th>
<th colspan="4">JIS 10K flange</th>
</tr>
<tr>
<th>φD</th>
<th>φd</th>
<th>aφb</th>
<th>Diameters</th>
</tr>
<tr>
<th>TBZ60</th>
<td>200</td>
<td>150</td>
<td>197</td>
<td>140</td>
<td>105</td>
<td>4-19</td>
<td>40A</td>
</tr>
<tr>
<th>TBZ150</th>
<td>220</td>
<td>158</td>
<td>211</td>
<td>155</td>
<td>120</td>
<td>4-19</td>
<td>50A</td>
</tr>
<tr>
<th>TBZ300</th>
<td>250</td>
<td>185</td>
<td>246</td>
<td>185</td>
<td>150</td>
<td>8-19</td>
<td>80A</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions of the turbine meter TBX</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-946" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbx.gif" alt="size_image_tbx" width="530" height="260" /></div>
<p class="size15">For TBX100F, the indicator can be moved freely, wherein the meter can accommodate the direction of the gas flow. The indicator can also be removed to be used as a remote display.</p>
<p class="size13 align_right">(Unit: mm)</p>
<table>
<tbody>
<tr>
<th>Model</th>
<th>L</th>
<th>H</th>
<th>W</th>
</tr>
<tr>
<th>TBX30</th>
<td>170</td>
<td>74</td>
<td>73</td>
</tr>
<tr>
<th>TBX100</th>
<td>200</td>
<td>100</td>
<td>85</td>
</tr>
<tr>
<th>TBX100F</th>
<td>200</td>
<td>161</td>
<td>φ155</td>
</tr>
<tr>
<th>TBX150F</th>
<td>200</td>
<td>148</td>
<td>φ155</td>
</tr>
</tbody>
</table>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bộ đo lưu lượng khí Aichi Tokei TBZ300-3.5N</title>
		<link>https://congcusanxuat.vn/san-pham/bo-do-luu-luong-khi-aichi-tokei-tbz300-3-5n/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 07:07:05 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12447</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/turbine-gas-meters-for-flow-management/">Bộ đo lưu lượng khí Aichi Tokei TBZ300-3.5N </a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Features</h1>
<p class="size15">Turbine meters in the TBZ and TBX series were developed for controlling the gas consumption of each piece of equipment such as compact boilers and various industrial furnaces.</p>
<p class="size15">The products realize a smart design with a lightweight and compact body and support a wide range of measurement including maximum working pressure and maximum measuring flow rate.</p>
<p class="size15">Furthermore, the built-in 2-system pulse transmitters enable you to establish a remote meter reading system and an energy control system.</p>
<p class="size15">The TBZ series even corrects temperature and pressure to allow you to read gas consumption in the standard conversion condition.</p>
<p class="size15 mb10">The external power supply model TBX-D has been newly added to the lineup of the TBX series. You can choose the model that would best suit your applications for better usability.</p>
<p class="size13 mb35">Note) TBX30, TBX100, and TBX100F are CE compliant. (Collaborative development product with Tokyo Gas Co., Ltd.)</p>
<p class="size15 mb35"><img loading="lazy" decoding="async" class="size-full wp-image-941" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/i_feature_2.jpg" alt="i_feature_2" width="290" height="200" /><br />
・The maximum working pressure covers low, medium and high pressures.<br />
・Free installation positions.<br />
・Equipped with two systems of pulse transmitter.<br />
・Supports a variety of gases and a wider range of applications.<br />
・LCD display that gives you more information.<br />
・Corrects temperature and pressure. (TBZ series).<br />
・Non-stop operation for seven years. (For the battery specifications)</p>
<p class="size15 bold">Application examples</p>
<p class="size15 mb35">・Manage and control gas flows of burning equipment such as burners, boilers and furnaces.<br />
・Manage and control flows of hot and chilled water generators in compact to medium sizes.<br />
・Manage and control flows of gas refrigerators.<br />
・Manage and control gas flows as a part of plant instrumentation.<br />
・For various experimental devices relating to gas flows.</p>
<p class="size15 bold">System drawing</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-944" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png" sizes="(max-width: 931px) 100vw, 931px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png 931w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_-300x104.png 300w" alt="system_" width="931" height="324" /></p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p class="size15 bold">The model with the correcting function (TBZ series)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th colspan="2">Basic model</th>
<th colspan="3">TBZ60</th>
<th colspan="3">TBZ150</th>
<th colspan="3">TBZ300</th>
</tr>
<tr>
<th rowspan="2">Model name</th>
<th>Flow rate correcting model (with the functions of temperature and pressure correction)</th>
<td>–</td>
<td>TBZ 60-3.5</td>
<td>TBZ 60-9.9</td>
<td>–</td>
<td>TBZ 150-3.5</td>
<td>TBZ 150-9.9</td>
<td>–</td>
<td>TBZ 300-3.5</td>
<td>TBZ 300-9.9</td>
</tr>
<tr>
<th>Actual flow rate model (without the functions of temperature and pressure)</th>
<td>TBZ 60-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 150-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 300-0</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td colspan="3">6～60m3/h</td>
<td colspan="3">12.5～150m3/h</td>
<td colspan="3">30～300m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="9">±1%FS and ±3%RS</td>
</tr>
<tr>
<th>Operator parts and temperature and pressure correction parts</th>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
</tr>
<tr>
<th rowspan="7">Display</th>
<th>Corrected gross accumulated flow rate (Only for the corrected flow rate model)</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Trip flow rate *2</th>
<td colspan="8">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>Large LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Corrected instantaneous flow rate (Only for the flow rate correction model)</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Temperature (Only for the models with temperature and pressure correction)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th>Pressure (Only for the corrected flow rate model)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td colspan="3">JIS 10K 40A flange</td>
<td colspan="3">JIS 10K 50A flange</td>
<td colspan="3">JIS 10K 80A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="9">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="9">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="9">Horizontal and Vertical (Display supports both directions.)</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="9">Indoor and outdoor * 5</td>
</tr>
<tr>
<th colspan="2">Case structure</th>
<td colspan="9">Drip-proof structure, IPX 2 equivalent (JIS-CO920)</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="9">Built-in lithium battery</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="9">Two systems of open collectors (corrected pulse and unadjusted pulse * 6)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 7</th>
<td colspan="9">100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="9">Main piping: Stainless steel; Flange: Steel; Display: Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Temperature sensor</th>
<td colspan="9">Platinum resistance temperature detector thermal sensor: JIS A class</td>
</tr>
<tr>
<th colspan="2">Pressure sensor</th>
<td colspan="9">Semiconductor type pressure sensor (High precision)</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td colspan="3">5.3kg</td>
<td colspan="3">6.0kg</td>
<td colspan="3">9.4kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13 mb35">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate for the actual flow rate model (without temperature and pressure correction).. *3. Under the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C.. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5. Avoid direct contact of water onto the meter if the meter is installed outdoors.. *6: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *7. TBZ uses corrected pulse while TBX uses unit pulse.</p>
<p class="size15 bold">Specifications of actual flow display model (TBX series)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th colspan="2">Model type</th>
<th>TBX30</th>
<th>TBX100</th>
<th>TBX100F</th>
<th>TBX150F</th>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td>4～30m3/h</td>
<td>10～100m3/h</td>
<td>10～100m3/h</td>
<td>12.5～150m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td colspan="4">100kPa</td>
</tr>
<tr>
<th>Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="4">±1%FS</td>
</tr>
<tr>
<th rowspan="3">Display</th>
<th>Trip flow rate *2</th>
<td colspan="3">Large LCD in 6 digits with minimum reading of 10 L</td>
<td>LCD in 6 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="3">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td>LCD in 3 digits with minimum reading of 0.1m3/h</td>
<td colspan="2">LCD in 4 digits with minimum reading of 0.1m3/h</td>
<td>LCD in 3 digits with minimum reading of 1m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td>Rc1 1/2、Rc1 1/4</td>
<td>Rc2</td>
<td colspan="2">JIS 10K 50A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="4">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="4">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="4">Horizontal and vertical</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="4">Indoor</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="4">Built-in lithium battery or external power supply (24 VDC)</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="4">Two systems of open-drain output (unit pulse and high-density pulse * 5)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 6</th>
<td colspan="4">TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="2">Aluminum alloy</td>
<td>Cast iron</td>
<td>Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td>0.8kg</td>
<td>1.8kg</td>
<td>7.0kg</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate. for the actual flow rate model (without temperature and pressure correction).. *3. In the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *6. TBZ uses a corrected pulse while TBX uses a unit pulse.</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<p class="size15 bold">Dimensions of the turbine meter TBZ</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-945" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbz.gif" alt="size_image_tbz" width="530" height="170" /></div>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Model</th>
<th rowspan="2">L</th>
<th rowspan="2">H</th>
<th rowspan="2">W</th>
<th colspan="4">JIS 10K flange</th>
</tr>
<tr>
<th>φD</th>
<th>φd</th>
<th>aφb</th>
<th>Diameters</th>
</tr>
<tr>
<th>TBZ60</th>
<td>200</td>
<td>150</td>
<td>197</td>
<td>140</td>
<td>105</td>
<td>4-19</td>
<td>40A</td>
</tr>
<tr>
<th>TBZ150</th>
<td>220</td>
<td>158</td>
<td>211</td>
<td>155</td>
<td>120</td>
<td>4-19</td>
<td>50A</td>
</tr>
<tr>
<th>TBZ300</th>
<td>250</td>
<td>185</td>
<td>246</td>
<td>185</td>
<td>150</td>
<td>8-19</td>
<td>80A</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions of the turbine meter TBX</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-946" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbx.gif" alt="size_image_tbx" width="530" height="260" /></div>
<p class="size15">For TBX100F, the indicator can be moved freely, wherein the meter can accommodate the direction of the gas flow. The indicator can also be removed to be used as a remote display.</p>
<p class="size13 align_right">(Unit: mm)</p>
<table>
<tbody>
<tr>
<th>Model</th>
<th>L</th>
<th>H</th>
<th>W</th>
</tr>
<tr>
<th>TBX30</th>
<td>170</td>
<td>74</td>
<td>73</td>
</tr>
<tr>
<th>TBX100</th>
<td>200</td>
<td>100</td>
<td>85</td>
</tr>
<tr>
<th>TBX100F</th>
<td>200</td>
<td>161</td>
<td>φ155</td>
</tr>
<tr>
<th>TBX150F</th>
<td>200</td>
<td>148</td>
<td>φ155</td>
</tr>
</tbody>
</table>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Strainer (sold separately)</h1>
<p class="size15">Make sure to install the strainer in the upstream side of the flow meter in order to maintain the performance of the flow meter as long as possible.</p>
<p class="size13 mb35">* Consideration of pressure loss will be necessary.</p>
<p class="size15 bold">Standard specifications</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th>Model</th>
<th>YKDS32</th>
<th>YKDS40</th>
<th>YKDS50</th>
<th>YF50</th>
<th>YDF40</th>
<th>YDF50</th>
<th>YDF80</th>
</tr>
<tr>
<th>Maximum operating pressure (kPa)</th>
<td>500</td>
<td>500</td>
<td>500</td>
<td>500</td>
<td>980</td>
<td>980</td>
<td>980</td>
</tr>
<tr>
<th>Body material</th>
<td>FCD450</td>
<td>FCD450</td>
<td>FCD450</td>
<td>FCD200</td>
<td>FCD-S</td>
<td>FCD-S</td>
<td>FCD-S</td>
</tr>
<tr>
<th>Diameter (A)</th>
<td>32</td>
<td>40</td>
<td>50</td>
<td>50</td>
<td>40</td>
<td>50</td>
<td>80</td>
</tr>
<tr>
<th>Connection</th>
<td>Rc1・1/4</td>
<td>Rc1・1/2</td>
<td>Rc2</td>
<td>JIS10K(FF)</td>
<td colspan="3">JIS10K(RF)</td>
</tr>
<tr>
<th>Mass (kg)</th>
<td>2.3</td>
<td>2.9</td>
<td>4.5</td>
<td>8.2</td>
<td>8.5</td>
<td>11</td>
<td>15</td>
</tr>
<tr>
<th>Supported models</th>
<td>TBX30(32A)</td>
<td>TBX30(40A)</td>
<td>TBX100</td>
<td>TBX100F・150F</td>
<td>TBZ60</td>
<td>TBZ150</td>
<td>TBZ300</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions: Screw type</p>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A</th>
<th>L</th>
<th>H (in approximate)</th>
</tr>
<tr>
<th>YKDS32</th>
<td>32</td>
<td>145</td>
<td>105</td>
</tr>
<tr>
<th>YKDS40</th>
<td>40</td>
<td>160</td>
<td>110</td>
</tr>
<tr>
<th>YKDS50</th>
<td>50</td>
<td>180</td>
<td>130</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-947" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/strainer_ys.gif" alt="strainer_ys" width="200" height="150" /></div>
<p class="size15 bold">Dimensions: Flange type</p>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A</th>
<th>L</th>
<th>H (in approximate)</th>
</tr>
<tr>
<th>YF50</th>
<td>50</td>
<td>220</td>
<td>130</td>
</tr>
<tr>
<th>YDF40</th>
<td>40</td>
<td>240</td>
<td>155</td>
</tr>
<tr>
<th>YDF50</th>
<td>50</td>
<td>250</td>
<td>170</td>
</tr>
<tr>
<th>YDF80</th>
<td>80</td>
<td>320</td>
<td>215</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-948" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/strainer_yf.gif" alt="strainer_yf" width="200" height="150" /></div>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bộ điều chỉnh áp lực gas Aichi Tokei A50N-2</title>
		<link>https://congcusanxuat.vn/san-pham/bo-dieu-chinh-ap-luc-gas-aichi-tokei-a50n-2/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:42:45 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12407</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/pressure-reducing-valves-a-n/">Bộ điều chỉnh áp lực gas Aichi Tokei A50N-2</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Model name</h1>
<p class="size15">・A10N – A50N-1 – General-use type<br />
・A20N – A50N-2 – High performance type<br />
・A40N – A75N-11 – Large capacity type</p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Features</h1>
<p class="size15 mb10">For industrial gas combustion equipment.</p>
<p class="size15">・Has a large capacity for the diameters that maintains accurate performance in a wide range of flow rates.<br />
・Ensures stable fuel control because the second pressure supplied to the device or equipment is kept constant even as the operating flow changes.<br />
・Built-in single soft sheet touch and balance diaphragm prevent leak to the secondary side when flow rate is zero. The pressure in the secondary side rarely changes even when the pressure in the primary side changes. (Note: Some models do not have a balanced diaphragm.)<br />
・Type 2 has better control with a larger main diaphragm than those of Type 1. Type 11 has larger valves to support larger capacity.</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p class="size15">・Pressure in the primary side P1 = 1 to 50 kPa<br />
・Pressure in the secondary side P2 = 0.5 to 30 kPa<br />
・Diameter = 1/4 to 3B (8 to 80 A)</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-981" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image6.gif" alt="size_image" width="530" height="260" /></div>
<div class="mb35">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A10N-1</th>
<th>A13N-1</th>
<th>A20N-1</th>
<th>A25N-1</th>
<th>A40N-1</th>
<th>A50N-1</th>
</tr>
<tr>
<th>A(mm)</th>
<td>60</td>
<td>74</td>
<td>112</td>
<td>140</td>
<td>140</td>
<td>220</td>
</tr>
<tr>
<th>B(mm)</th>
<td>78</td>
<td>108</td>
<td>105</td>
<td>141</td>
<td>144</td>
<td>221</td>
</tr>
<tr>
<th>C(mm)</th>
<td>20</td>
<td>21</td>
<td>25</td>
<td>27</td>
<td>30</td>
<td>51</td>
</tr>
<tr>
<th>D(mm)</th>
<td>□73</td>
<td>φ116</td>
<td>φ116</td>
<td>φ169</td>
<td>φ169</td>
<td>φ246</td>
</tr>
<tr>
<th>E</th>
<td>Rc3/8</td>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc1</td>
<td>Rc11/2</td>
<td>Rc2</td>
</tr>
<tr>
<th>Mass (kg)</th>
<td>0.2</td>
<td>1.0</td>
<td>0.7</td>
<td>1.3</td>
<td>1.4</td>
<td>9.3</td>
</tr>
</tbody>
</table>
</div>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A20N-2</th>
<th>A25N-2</th>
<th>A40N-2</th>
<th>A50N-2</th>
<th>A40N-11</th>
<th>A50N-11</th>
</tr>
<tr>
<th>A(mm)</th>
<td>112</td>
<td>140</td>
<td>140</td>
<td>220</td>
<td>200</td>
<td>250</td>
</tr>
<tr>
<th>B(mm)</th>
<td>135</td>
<td>200</td>
<td>203</td>
<td>281</td>
<td>262</td>
<td>318</td>
</tr>
<tr>
<th>C(mm)</th>
<td>25</td>
<td>27</td>
<td>30</td>
<td>51</td>
<td>53</td>
<td>64</td>
</tr>
<tr>
<th>D(mm)</th>
<td>φ169</td>
<td>φ246</td>
<td>φ246</td>
<td>φ330</td>
<td>φ246</td>
<td>φ330</td>
</tr>
<tr>
<th>E</th>
<td>Rc3/4</td>
<td>Rc1</td>
<td>Rc11/2</td>
<td>Rc2</td>
<td>Rc11/2</td>
<td>Rc2</td>
</tr>
<tr>
<th>Mass (kg)</th>
<td>1.5</td>
<td>5.5</td>
<td>5.5</td>
<td>15.0</td>
<td>7.0</td>
<td>18.0</td>
</tr>
</tbody>
</table>
</div>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Van giảm áp Aichi Tokei A20P-2</title>
		<link>https://congcusanxuat.vn/san-pham/van-giam-ap-aichi-tokei-a20p-2/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:39:46 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12404</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/pressure-equalizing-valves-a-p/">Van giảm áp Aichi Tokei A20P-2</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Model name</h1>
<p>A13P to A50P-2 – High performance type</p>
</section>
<section id="overview" class="product_section_wrap">
<h1 class="section_title">Features</h1>
<p>– These types of pressure equalizing valves have the same capacity (in-house comparison) as the one-class higher model in diameter.<br />
– Has a wide range of flow rate (up to 1/100 under the optimum condition) and maintains an accurate air-fuel ratio with good control to the small-flow-rate zone.<br />
– Efficient and energy saving combustion can be achieved by introducing this pressure equalizing valve.</p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p>Standard specifications<br />
Pressure in the primary side P1 = 1 to 20 kPa<br />
Pressure in the secondary side P2 = 0 kPa<br />
Diameter = 1/2 to 2B (15 to 50 A)</p>
<p>Capacity</p>
<table>
<tbody>
<tr>
<th colspan="2">Model</th>
<th>A13P-2</th>
<th>A20P-2</th>
<th>A25P-2</th>
<th>A40P-2</th>
<th>A50P-2</th>
</tr>
<tr>
<th rowspan="4">Differential pressure</th>
<th>0.5kPa</th>
<td>6</td>
<td>11</td>
<td>22</td>
<td>45</td>
<td>90</td>
</tr>
<tr>
<th>1kPa</th>
<td>8</td>
<td>15</td>
<td>31</td>
<td>63</td>
<td>127</td>
</tr>
<tr>
<th>1.5kPa</th>
<td>10</td>
<td>19</td>
<td>38</td>
<td>78</td>
<td>155</td>
</tr>
<tr>
<th>2 kPa or higher</th>
<td>12</td>
<td>23</td>
<td>45</td>
<td>90</td>
<td>180</td>
</tr>
</tbody>
</table>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<p>Dimensions</p>
<table>
<tbody>
<tr>
<th>Model</th>
<th>A13P-2</th>
<th>A20P-2</th>
<th>A25P-2</th>
<th>A40P-2</th>
<th>A50P-2</th>
</tr>
<tr>
<th>A(mm)</th>
<td>80</td>
<td>112</td>
<td>140</td>
<td>180</td>
<td>220</td>
</tr>
<tr>
<th>C(mm)</th>
<td>164</td>
<td>222</td>
<td>272</td>
<td>320</td>
<td>435</td>
</tr>
<tr>
<th>D(mm)</th>
<td>37</td>
<td>45</td>
<td>58</td>
<td>75</td>
<td>95</td>
</tr>
<tr>
<th>E(mm)</th>
<td>150</td>
<td>206</td>
<td>250</td>
<td>326</td>
<td>420</td>
</tr>
<tr>
<th>F</th>
<td>Rc1/2</td>
<td>Rc3/4</td>
<td>Rc1</td>
<td>Rc11/2</td>
<td>Rc2</td>
</tr>
<tr>
<th>Mass (kg)</th>
<td>1.3</td>
<td>3.2</td>
<td>4.2</td>
<td>8.8</td>
<td>15.8</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Đồng hồ đo lưu lượng gas Aichi Tokei TBX30/L4</title>
		<link>https://congcusanxuat.vn/san-pham/dong-ho-do-luu-luong-gas-aichi-tokei-tbx30-l4/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:36:34 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12403</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/turbine-gas-meters-for-flow-management/">Đồng hồ đo lưu lượng gas Aichi Tokei TBX30/L4</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Features</h1>
<p class="size15">Turbine meters in the TBZ and TBX series were developed for controlling the gas consumption of each piece of equipment such as compact boilers and various industrial furnaces.</p>
<p class="size15">The products realize a smart design with a lightweight and compact body and support a wide range of measurement including maximum working pressure and maximum measuring flow rate.</p>
<p class="size15">Furthermore, the built-in 2-system pulse transmitters enable you to establish a remote meter reading system and an energy control system.</p>
<p class="size15">The TBZ series even corrects temperature and pressure to allow you to read gas consumption in the standard conversion condition.</p>
<p class="size15 mb10">The external power supply model TBX-D has been newly added to the lineup of the TBX series. You can choose the model that would best suit your applications for better usability.</p>
<p class="size13 mb35">Note) TBX30, TBX100, and TBX100F are CE compliant. (Collaborative development product with Tokyo Gas Co., Ltd.)</p>
<p class="size15 mb35"><img loading="lazy" decoding="async" class="size-full wp-image-941" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/i_feature_2.jpg" alt="i_feature_2" width="290" height="200" /><br />
・The maximum working pressure covers low, medium and high pressures.<br />
・Free installation positions.<br />
・Equipped with two systems of pulse transmitter.<br />
・Supports a variety of gases and a wider range of applications.<br />
・LCD display that gives you more information.<br />
・Corrects temperature and pressure. (TBZ series).<br />
・Non-stop operation for seven years. (For the battery specifications)</p>
<p class="size15 bold">Application examples</p>
<p class="size15 mb35">・Manage and control gas flows of burning equipment such as burners, boilers and furnaces.<br />
・Manage and control flows of hot and chilled water generators in compact to medium sizes.<br />
・Manage and control flows of gas refrigerators.<br />
・Manage and control gas flows as a part of plant instrumentation.<br />
・For various experimental devices relating to gas flows.</p>
<p class="size15 bold">System drawing</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-944" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png" sizes="(max-width: 931px) 100vw, 931px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png 931w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_-300x104.png 300w" alt="system_" width="931" height="324" /></p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p class="size15 bold">The model with the correcting function (TBZ series)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th colspan="2">Basic model</th>
<th colspan="3">TBZ60</th>
<th colspan="3">TBZ150</th>
<th colspan="3">TBZ300</th>
</tr>
<tr>
<th rowspan="2">Model name</th>
<th>Flow rate correcting model (with the functions of temperature and pressure correction)</th>
<td>–</td>
<td>TBZ 60-3.5</td>
<td>TBZ 60-9.9</td>
<td>–</td>
<td>TBZ 150-3.5</td>
<td>TBZ 150-9.9</td>
<td>–</td>
<td>TBZ 300-3.5</td>
<td>TBZ 300-9.9</td>
</tr>
<tr>
<th>Actual flow rate model (without the functions of temperature and pressure)</th>
<td>TBZ 60-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 150-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 300-0</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td colspan="3">6～60m3/h</td>
<td colspan="3">12.5～150m3/h</td>
<td colspan="3">30～300m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="9">±1%FS and ±3%RS</td>
</tr>
<tr>
<th>Operator parts and temperature and pressure correction parts</th>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
</tr>
<tr>
<th rowspan="7">Display</th>
<th>Corrected gross accumulated flow rate (Only for the corrected flow rate model)</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Trip flow rate *2</th>
<td colspan="8">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>Large LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Corrected instantaneous flow rate (Only for the flow rate correction model)</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Temperature (Only for the models with temperature and pressure correction)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th>Pressure (Only for the corrected flow rate model)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td colspan="3">JIS 10K 40A flange</td>
<td colspan="3">JIS 10K 50A flange</td>
<td colspan="3">JIS 10K 80A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="9">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="9">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="9">Horizontal and Vertical (Display supports both directions.)</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="9">Indoor and outdoor * 5</td>
</tr>
<tr>
<th colspan="2">Case structure</th>
<td colspan="9">Drip-proof structure, IPX 2 equivalent (JIS-CO920)</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="9">Built-in lithium battery</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="9">Two systems of open collectors (corrected pulse and unadjusted pulse * 6)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 7</th>
<td colspan="9">100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="9">Main piping: Stainless steel; Flange: Steel; Display: Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Temperature sensor</th>
<td colspan="9">Platinum resistance temperature detector thermal sensor: JIS A class</td>
</tr>
<tr>
<th colspan="2">Pressure sensor</th>
<td colspan="9">Semiconductor type pressure sensor (High precision)</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td colspan="3">5.3kg</td>
<td colspan="3">6.0kg</td>
<td colspan="3">9.4kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13 mb35">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate for the actual flow rate model (without temperature and pressure correction).. *3. Under the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C.. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5. Avoid direct contact of water onto the meter if the meter is installed outdoors.. *6: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *7. TBZ uses corrected pulse while TBX uses unit pulse.</p>
<p class="size15 bold">Specifications of actual flow display model (TBX series)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th colspan="2">Model type</th>
<th>TBX30</th>
<th>TBX100</th>
<th>TBX100F</th>
<th>TBX150F</th>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td>4～30m3/h</td>
<td>10～100m3/h</td>
<td>10～100m3/h</td>
<td>12.5～150m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td colspan="4">100kPa</td>
</tr>
<tr>
<th>Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="4">±1%FS</td>
</tr>
<tr>
<th rowspan="3">Display</th>
<th>Trip flow rate *2</th>
<td colspan="3">Large LCD in 6 digits with minimum reading of 10 L</td>
<td>LCD in 6 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="3">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td>LCD in 3 digits with minimum reading of 0.1m3/h</td>
<td colspan="2">LCD in 4 digits with minimum reading of 0.1m3/h</td>
<td>LCD in 3 digits with minimum reading of 1m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td>Rc1 1/2、Rc1 1/4</td>
<td>Rc2</td>
<td colspan="2">JIS 10K 50A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="4">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="4">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="4">Horizontal and vertical</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="4">Indoor</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="4">Built-in lithium battery or external power supply (24 VDC)</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="4">Two systems of open-drain output (unit pulse and high-density pulse * 5)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 6</th>
<td colspan="4">TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="2">Aluminum alloy</td>
<td>Cast iron</td>
<td>Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td>0.8kg</td>
<td>1.8kg</td>
<td>7.0kg</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate. for the actual flow rate model (without temperature and pressure correction).. *3. In the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *6. TBZ uses a corrected pulse while TBX uses a unit pulse.</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<p class="size15 bold">Dimensions of the turbine meter TBZ</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-945" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbz.gif" alt="size_image_tbz" width="530" height="170" /></div>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Model</th>
<th rowspan="2">L</th>
<th rowspan="2">H</th>
<th rowspan="2">W</th>
<th colspan="4">JIS 10K flange</th>
</tr>
<tr>
<th>φD</th>
<th>φd</th>
<th>aφb</th>
<th>Diameters</th>
</tr>
<tr>
<th>TBZ60</th>
<td>200</td>
<td>150</td>
<td>197</td>
<td>140</td>
<td>105</td>
<td>4-19</td>
<td>40A</td>
</tr>
<tr>
<th>TBZ150</th>
<td>220</td>
<td>158</td>
<td>211</td>
<td>155</td>
<td>120</td>
<td>4-19</td>
<td>50A</td>
</tr>
<tr>
<th>TBZ300</th>
<td>250</td>
<td>185</td>
<td>246</td>
<td>185</td>
<td>150</td>
<td>8-19</td>
<td>80A</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions of the turbine meter TBX</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-946" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbx.gif" alt="size_image_tbx" width="530" height="260" /></div>
<p class="size15">For TBX100F, the indicator can be moved freely, wherein the meter can accommodate the direction of the gas flow. The indicator can also be removed to be used as a remote display.</p>
<p class="size13 align_right">(Unit: mm)</p>
<table>
<tbody>
<tr>
<th>Model</th>
<th>L</th>
<th>H</th>
<th>W</th>
</tr>
<tr>
<th>TBX30</th>
<td>170</td>
<td>74</td>
<td>73</td>
</tr>
<tr>
<th>TBX100</th>
<td>200</td>
<td>100</td>
<td>85</td>
</tr>
<tr>
<th>TBX100F</th>
<td>200</td>
<td>161</td>
<td>φ155</td>
</tr>
<tr>
<th>TBX150F</th>
<td>200</td>
<td>148</td>
<td>φ155</td>
</tr>
</tbody>
</table>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Strainer (sold separately)</h1>
<p class="size15">Make sure to install the strainer in the upstream side of the flow meter in order to maintain the performance of the flow meter as long as possible.</p>
<p class="size13 mb35">* Consideration of pressure loss will be necessary.</p>
<p class="size15 bold">Standard specifications</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th>Model</th>
<th>YKDS32</th>
<th>YKDS40</th>
<th>YKDS50</th>
<th>YF50</th>
<th>YDF40</th>
<th>YDF50</th>
<th>YDF80</th>
</tr>
<tr>
<th>Maximum operating pressure (kPa)</th>
<td>500</td>
<td>500</td>
<td>500</td>
<td>500</td>
<td>980</td>
<td>980</td>
<td>980</td>
</tr>
<tr>
<th>Body material</th>
<td>FCD450</td>
<td>FCD450</td>
<td>FCD450</td>
<td>FCD200</td>
<td>FCD-S</td>
<td>FCD-S</td>
<td>FCD-S</td>
</tr>
<tr>
<th>Diameter (A)</th>
<td>32</td>
<td>40</td>
<td>50</td>
<td>50</td>
<td>40</td>
<td>50</td>
<td>80</td>
</tr>
<tr>
<th>Connection</th>
<td>Rc1・1/4</td>
<td>Rc1・1/2</td>
<td>Rc2</td>
<td>JIS10K(FF)</td>
<td colspan="3">JIS10K(RF)</td>
</tr>
<tr>
<th>Mass (kg)</th>
<td>2.3</td>
<td>2.9</td>
<td>4.5</td>
<td>8.2</td>
<td>8.5</td>
<td>11</td>
<td>15</td>
</tr>
<tr>
<th>Supported models</th>
<td>TBX30(32A)</td>
<td>TBX30(40A)</td>
<td>TBX100</td>
<td>TBX100F・150F</td>
<td>TBZ60</td>
<td>TBZ150</td>
<td>TBZ300</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions: Screw type</p>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A</th>
<th>L</th>
<th>H (in approximate)</th>
</tr>
<tr>
<th>YKDS32</th>
<td>32</td>
<td>145</td>
<td>105</td>
</tr>
<tr>
<th>YKDS40</th>
<td>40</td>
<td>160</td>
<td>110</td>
</tr>
<tr>
<th>YKDS50</th>
<td>50</td>
<td>180</td>
<td>130</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-947" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/strainer_ys.gif" alt="strainer_ys" width="200" height="150" /></div>
<p class="size15 bold">Dimensions: Flange type</p>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Model</th>
<th>A</th>
<th>L</th>
<th>H (in approximate)</th>
</tr>
<tr>
<th>YF50</th>
<td>50</td>
<td>220</td>
<td>130</td>
</tr>
<tr>
<th>YDF40</th>
<td>40</td>
<td>240</td>
<td>155</td>
</tr>
<tr>
<th>YDF50</th>
<td>50</td>
<td>250</td>
<td>170</td>
</tr>
<tr>
<th>YDF80</th>
<td>80</td>
<td>320</td>
<td>215</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-948" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/strainer_yf.gif" alt="strainer_yf" width="200" height="150" /></div>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Đồng hồ đo áp suất Aichi Tokei TBX100/L</title>
		<link>https://congcusanxuat.vn/san-pham/dong-ho-do-ap-suat-aichi-tokei-tbx100-l/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:33:55 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12400</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/turbine-gas-meters-for-flow-management/">Đồng hồ đo áp suất Aichi Tokei TBX100/L</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Features</h1>
<p class="size15">Turbine meters in the TBZ and TBX series were developed for controlling the gas consumption of each piece of equipment such as compact boilers and various industrial furnaces.</p>
<p class="size15">The products realize a smart design with a lightweight and compact body and support a wide range of measurement including maximum working pressure and maximum measuring flow rate.</p>
<p class="size15">Furthermore, the built-in 2-system pulse transmitters enable you to establish a remote meter reading system and an energy control system.</p>
<p class="size15">The TBZ series even corrects temperature and pressure to allow you to read gas consumption in the standard conversion condition.</p>
<p class="size15 mb10">The external power supply model TBX-D has been newly added to the lineup of the TBX series. You can choose the model that would best suit your applications for better usability.</p>
<p class="size13 mb35">Note) TBX30, TBX100, and TBX100F are CE compliant. (Collaborative development product with Tokyo Gas Co., Ltd.)</p>
<p class="size15 mb35"><img loading="lazy" decoding="async" class="size-full wp-image-941" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/i_feature_2.jpg" alt="i_feature_2" width="290" height="200" /><br />
・The maximum working pressure covers low, medium and high pressures.<br />
・Free installation positions.<br />
・Equipped with two systems of pulse transmitter.<br />
・Supports a variety of gases and a wider range of applications.<br />
・LCD display that gives you more information.<br />
・Corrects temperature and pressure. (TBZ series).<br />
・Non-stop operation for seven years. (For the battery specifications)</p>
<p class="size15 bold">Application examples</p>
<p class="size15 mb35">・Manage and control gas flows of burning equipment such as burners, boilers and furnaces.<br />
・Manage and control flows of hot and chilled water generators in compact to medium sizes.<br />
・Manage and control flows of gas refrigerators.<br />
・Manage and control gas flows as a part of plant instrumentation.<br />
・For various experimental devices relating to gas flows.</p>
<p class="size15 bold">System drawing</p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-944" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png" sizes="(max-width: 931px) 100vw, 931px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_.png 931w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/system_-300x104.png 300w" alt="system_" width="931" height="324" /></p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<p class="size15 bold">The model with the correcting function (TBZ series)</p>
<div class="mb10">
<table>
<tbody>
<tr>
<th colspan="2">Basic model</th>
<th colspan="3">TBZ60</th>
<th colspan="3">TBZ150</th>
<th colspan="3">TBZ300</th>
</tr>
<tr>
<th rowspan="2">Model name</th>
<th>Flow rate correcting model (with the functions of temperature and pressure correction)</th>
<td>–</td>
<td>TBZ 60-3.5</td>
<td>TBZ 60-9.9</td>
<td>–</td>
<td>TBZ 150-3.5</td>
<td>TBZ 150-9.9</td>
<td>–</td>
<td>TBZ 300-3.5</td>
<td>TBZ 300-9.9</td>
</tr>
<tr>
<th>Actual flow rate model (without the functions of temperature and pressure)</th>
<td>TBZ 60-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 150-0</td>
<td>–</td>
<td>–</td>
<td>TBZ 300-0</td>
<td>–</td>
<td>–</td>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td colspan="3">6～60m3/h</td>
<td colspan="3">12.5～150m3/h</td>
<td colspan="3">30～300m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
<td>980kPa</td>
<td>350kPa</td>
<td>980kPa</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="9">±1%FS and ±3%RS</td>
</tr>
<tr>
<th>Operator parts and temperature and pressure correction parts</th>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
<td>–</td>
<td>±2% RSmax</td>
<td>±3% RSmax</td>
</tr>
<tr>
<th rowspan="7">Display</th>
<th>Corrected gross accumulated flow rate (Only for the corrected flow rate model)</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Trip flow rate *2</th>
<td colspan="8">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>Large LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="8">Large LCD in 9 digits with minimum reading of 10 L</td>
<td>Large LCD in 9 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Corrected instantaneous flow rate (Only for the flow rate correction model)</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td colspan="8">LCD in 4 digits with minimum reading of 0.1 m3/h</td>
<td>LCD in 4 digits with minimum reading of 1 m3/h</td>
</tr>
<tr>
<th>Temperature (Only for the models with temperature and pressure correction)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th>Pressure (Only for the corrected flow rate model)</th>
<td colspan="9">LCD in 3 digits with minimum reading of 0.1 m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td colspan="3">JIS 10K 40A flange</td>
<td colspan="3">JIS 10K 50A flange</td>
<td colspan="3">JIS 10K 80A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="9">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="9">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="9">Horizontal and Vertical (Display supports both directions.)</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="9">Indoor and outdoor * 5</td>
</tr>
<tr>
<th colspan="2">Case structure</th>
<td colspan="9">Drip-proof structure, IPX 2 equivalent (JIS-CO920)</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="9">Built-in lithium battery</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="9">Two systems of open collectors (corrected pulse and unadjusted pulse * 6)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 7</th>
<td colspan="9">100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="9">Main piping: Stainless steel; Flange: Steel; Display: Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Temperature sensor</th>
<td colspan="9">Platinum resistance temperature detector thermal sensor: JIS A class</td>
</tr>
<tr>
<th colspan="2">Pressure sensor</th>
<td colspan="9">Semiconductor type pressure sensor (High precision)</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td colspan="3">5.3kg</td>
<td colspan="3">6.0kg</td>
<td colspan="3">9.4kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13 mb35">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate for the actual flow rate model (without temperature and pressure correction).. *3. Under the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C.. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5. Avoid direct contact of water onto the meter if the meter is installed outdoors.. *6: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *7. TBZ uses corrected pulse while TBX uses unit pulse.</p>
<p class="size15 bold">Specifications of actual flow display model (TBX series)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th colspan="2">Model type</th>
<th>TBX30</th>
<th>TBX100</th>
<th>TBX100F</th>
<th>TBX150F</th>
</tr>
<tr>
<th colspan="2">Operating flow rate range *1</th>
<td>4～30m3/h</td>
<td>10～100m3/h</td>
<td>10～100m3/h</td>
<td>12.5～150m3/h</td>
</tr>
<tr>
<th colspan="2">Maximum operating pressure</th>
<td colspan="4">100kPa</td>
</tr>
<tr>
<th>Accuracy</th>
<th>Flow rate measuring parts</th>
<td colspan="4">±1%FS</td>
</tr>
<tr>
<th rowspan="3">Display</th>
<th>Trip flow rate *2</th>
<td colspan="3">Large LCD in 6 digits with minimum reading of 10 L</td>
<td>LCD in 6 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted gross accumulated flow rate *3</th>
<td colspan="3">Large LCD in 8 digits with minimum reading of 10 L</td>
<td>LCD in 8 digits with minimum reading of 100 L</td>
</tr>
<tr>
<th>Unadjusted instantaneous flow rate</th>
<td>LCD in 3 digits with minimum reading of 0.1m3/h</td>
<td colspan="2">LCD in 4 digits with minimum reading of 0.1m3/h</td>
<td>LCD in 3 digits with minimum reading of 1m3/h</td>
</tr>
<tr>
<th colspan="2">Diameters of connected parts</th>
<td>Rc1 1/2、Rc1 1/4</td>
<td>Rc2</td>
<td colspan="2">JIS 10K 50A flange</td>
</tr>
<tr>
<th colspan="2">Operating temperature range</th>
<td colspan="4">－10℃～＋60℃</td>
</tr>
<tr>
<th colspan="2">Measurable gases *4</th>
<td colspan="4">Town gas, LPG, nitrogen, etc.</td>
</tr>
<tr>
<th colspan="2">Mounting position</th>
<td colspan="4">Horizontal and vertical</td>
</tr>
<tr>
<th colspan="2">Installation location</th>
<td colspan="4">Indoor</td>
</tr>
<tr>
<th colspan="2">Power source</th>
<td colspan="4">Built-in lithium battery or external power supply (24 VDC)</td>
</tr>
<tr>
<th colspan="2">Output signal</th>
<td colspan="4">Two systems of open-drain output (unit pulse and high-density pulse * 5)</td>
</tr>
<tr>
<th colspan="2">Standard pulse unit width * 6</th>
<td colspan="4">TBX30 and TBX100: 10 L/P; TBX150: 100 L/P Maximum load: 24 VDC and 20 mA; Pulse width: 40 msec</td>
</tr>
<tr>
<th colspan="2">Materials</th>
<td colspan="2">Aluminum alloy</td>
<td>Cast iron</td>
<td>Aluminum alloy</td>
</tr>
<tr>
<th colspan="2">Mass</th>
<td>0.8kg</td>
<td>1.8kg</td>
<td>7.0kg</td>
<td>2.5kg</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">*1. Operating flow rate range is the range of the actual flow (unadjusted flow rate).. *2. Corrected trip accumulated flow rate for the flow rate correction model (with temperature and pressure correction) and unadjusted trip accumulated flow rate. for the actual flow rate model (without temperature and pressure correction).. *3. In the conditions of pressure 100 kPa or higher for the -3.5 model and 350 kPa or higher for the – 9.9 model where the temperature is at 25°C. *4. Prevent oil mist (Carbide grade C5 or higher), dust particles and the like from entering into the meter.. *5: Unadjusted pulse and high-density pulse are the actual pulse synchronized with the rotation of impellers.. *6. TBZ uses a corrected pulse while TBX uses a unit pulse.</p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<p class="size15 bold">Dimensions of the turbine meter TBZ</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-945" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbz.gif" alt="size_image_tbz" width="530" height="170" /></div>
<p class="size13 align_right">(Unit: mm)</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Model</th>
<th rowspan="2">L</th>
<th rowspan="2">H</th>
<th rowspan="2">W</th>
<th colspan="4">JIS 10K flange</th>
</tr>
<tr>
<th>φD</th>
<th>φd</th>
<th>aφb</th>
<th>Diameters</th>
</tr>
<tr>
<th>TBZ60</th>
<td>200</td>
<td>150</td>
<td>197</td>
<td>140</td>
<td>105</td>
<td>4-19</td>
<td>40A</td>
</tr>
<tr>
<th>TBZ150</th>
<td>220</td>
<td>158</td>
<td>211</td>
<td>155</td>
<td>120</td>
<td>4-19</td>
<td>50A</td>
</tr>
<tr>
<th>TBZ300</th>
<td>250</td>
<td>185</td>
<td>246</td>
<td>185</td>
<td>150</td>
<td>8-19</td>
<td>80A</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Dimensions of the turbine meter TBX</p>
<div class="mb10"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-946" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/size_image_tbx.gif" alt="size_image_tbx" width="530" height="260" /></div>
<p class="size15">For TBX100F, the indicator can be moved freely, wherein the meter can accommodate the direction of the gas flow. The indicator can also be removed to be used as a remote display.</p>
<p class="size13 align_right">(Unit: mm)</p>
<table>
<tbody>
<tr>
<th>Model</th>
<th>L</th>
<th>H</th>
<th>W</th>
</tr>
<tr>
<th>TBX30</th>
<td>170</td>
<td>74</td>
<td>73</td>
</tr>
<tr>
<th>TBX100</th>
<td>200</td>
<td>100</td>
<td>85</td>
</tr>
<tr>
<th>TBX100F</th>
<td>200</td>
<td>161</td>
<td>φ155</td>
</tr>
<tr>
<th>TBX150F</th>
<td>200</td>
<td>148</td>
<td>φ155</td>
</tr>
</tbody>
</table>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Đồng hồ Aichi Tokei NW20-PTN</title>
		<link>https://congcusanxuat.vn/san-pham/dong-ho-aichi-tokei-nw20-ptn/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:25:15 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12399</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/nwnw-p-series/">Đồng hồ Aichi Tokei NW20-PTN </a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Feature</h1>
<p class="size15 mb20">・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the vane wheel type measuring principle ・Measurement of various liquids ・Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) ・Value holding function for Instantaneous Flow-Rate indication ・Pulse output function (Option)</p>
<p class="size15 mb20">Model NW (Local display type) Model NW-P (With pulse output)</p>
<p class="size15 bold">Enhanced basic functions, user friendliness and cost efficiency are the key points</p>
<p class="size15 mb20">ND series offers high accuracy measurement of not only cold and warm water but also pure water, chemical fluids, etc. It is light-weighted compact body and is compatible with various kinds of fluids with the carefully selected casing materials such as PP, ETFE, PPO, etc., and with the highly sensitive magnetic sensor of our own development. This series is therefore widely applicable for various flow measurements and its control and monitoring as well.</p>
<p class="size15 bold">Flowsensor Applications</p>
<p class="size15 mb20">・To control of warm water temperature ・To constantly supply water and warm water ・To monitor coolant, etc. ・To proportionally inject chemical fluids ・To control pressure loss of filters</p>
</section>
<section id="overview" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW05-NTN</th>
<th>NW05-PTN</th>
<th>NW05-TTN</th>
<th>NW10-NTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW05-NTP</th>
<th>NW05-PTP</th>
<th>NW05-TTP</th>
<th>NW10-NTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td colspan="3">0.3 – 3L/min</td>
<td>1.5 – 20L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="3">±2%RS±0.05L/min</td>
<td>±2% RS±0.2L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td colspan="3">Not more than 12kPa (At the time of 3L/min)</td>
<td>Not more than 20kPa (At the time of 20L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa・s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not morethan 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="3">10mL/p</td>
<td>1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="3">0.05L/min</td>
<td>0.2L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="3">00.00L/min</td>
<td>000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="3">000000.00L</td>
<td>0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="4">R1/2</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 280g</td>
<td>Approx. 250g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>Denatured PPO</td>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane wheel</th>
<td colspan="2">POM</td>
<td>ETFE</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>PA</td>
<td>ETFE</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>NBR</td>
<td colspan="2">FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td colspan="3">Sa-Co *1</td>
<td>Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW10-PTN</th>
<th>NW10-TTN</th>
<th>NW20-NTN</th>
<th>NW20-PTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW10-PTP</th>
<th>NW10-TTP</th>
<th>NW20-NTP</th>
<th>NW20-PTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td>1.5-20L/min</td>
<td>1.0-10L/min</td>
<td colspan="2">3.0-60L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="2">±2%RS±0.2L/min</td>
<td colspan="2">±2% RS±0.5L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td>Not more than 20kPa (At the time of 20L/min)</td>
<td>Not more than 15kPa (At the time of 10L/min)</td>
<td colspan="2">Not more than 60kPa (At the time of 60L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa·s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="4">1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="2">0.2L/min</td>
<td colspan="2">0.5L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="4">000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="4">0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="2">R1/2</td>
<td colspan="2">R3/4</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 250g</td>
<td>Approx. 500g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
<td>PP</td>
</tr>
<tr>
<th>Vane wheel</th>
<td>POM</td>
<td>ETFE</td>
<td colspan="2">POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>ETFE</td>
<td colspan="2">SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td colspan="2">FKM</td>
<td>NBR</td>
<td>FKM</td>
</tr>
<tr>
<th>Magnet</th>
<td>Ba-Fe</td>
<td>Sa-Co *1</td>
<td colspan="2">Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">Any installation position other than the standard installation position is not available for NW05-TTN, NW05-TTP, NW10-TTN, and NW10-TTP. *1: The magnet does not touch liquid.</p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Mode</th>
<th>NW05</th>
<th>NW10</th>
<th>NW20</th>
</tr>
<tr>
<th>A(mm)</th>
<td>80</td>
<td>80</td>
<td>110</td>
</tr>
<tr>
<th>B(mm)</th>
<td>87</td>
<td>87</td>
<td>105.5</td>
</tr>
<tr>
<th>C(mm)</th>
<td>52</td>
<td>52</td>
<td>74</td>
</tr>
<tr>
<th>D(mm)</th>
<td>11</td>
<td>11</td>
<td>16</td>
</tr>
<tr>
<th>E(mm)</th>
<td>25</td>
<td>25</td>
<td>35.5</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35">
<p><img loading="lazy" decoding="async" class="alignnone wp-image-803 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/nw_glaf.gif" alt="nw_glaf" width="473" height="249" /></p>
<p class="size15 bold">Standard installation position</p>
<p class="size15">The standard installation position is that the display is facing upwards. * The display is able to be revolved.</p>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone wp-image-804 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/nw_position.gif" alt="nw_position" width="300" height="235" /></div>
<p class="size15 bold">Materials -Abbreviations</p>
<table>
<tbody>
<tr>
<th>Denatured PPO</th>
<td>Denatured Polyphenylene oxide</td>
</tr>
<tr>
<th>PP</th>
<td>Polypropylene</td>
</tr>
<tr>
<th>ETFE</th>
<td>Ethylene-tetrafiuoro ethylene</td>
</tr>
<tr>
<th>POM</th>
<td>Polyacetal or Polyoxymethylene</td>
</tr>
<tr>
<th>SUS304</th>
<td>Stainless steel 304</td>
</tr>
<tr>
<th>PA</th>
<td>Polyamide</td>
</tr>
<tr>
<th>NBR</th>
<td>Acrylonitrile-Butadiene Rubber</td>
</tr>
<tr>
<th>FKM</th>
<td>Fluoro Rubber</td>
</tr>
<tr>
<th>Sa-Co</th>
<td>Samarium-Cobalt</td>
</tr>
<tr>
<th>Ba-Fe</th>
<td>Barium-ferrite</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Handling Instructions</h1>
<p class="size15 mb20">Observe the following handling instructions and precautions to obtain maximum performance of the Flowsensor / Flowmeter.</p>
<p class="size15 bold">CAUTIONS IN MOUNTING</p>
<p class="size15 mb10">1. The flowing direction of the fluid, when mounting, must be matched to the arrow mark on the case that indicates the direction of flow.</p>
<p class="size15 mb10">2. A straight pipe with uniform inner diameter must be connected to the inlet. Accuracy is adversely affected if the pipe is bent or the inner diameter is uneven.</p>
<p class="size15 mb10">3. The inner diameter of the inlet pipe must be greater than the nozzle diameter of the Flowsensor / Flowmeter.</p>
<div class="mb20">
<table>
<tbody>
<tr>
<th>Type</th>
<th>Inner D, of inlet pipe</th>
<th>Length of straight pipe at inlet</th>
</tr>
<tr>
<th>ND05,NW05</th>
<td>5.5 mm or greater</td>
<td>Greater than 50 mm from the end of the Flowsensor / Flowmeter</td>
</tr>
<tr>
<th>ND10,NW10</th>
<td>10.5 mm or greater</td>
<td rowspan="2">Greater than 100 mm from the end of the Flowsensor / Flowmeter</td>
</tr>
<tr>
<th>ND20,NW20</th>
<td>15.5 mm or greater</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 mb10">4. If pulsation occurs in the flow of the fluid, measurement accuracy is adversely affected. When a pump is used to circulate the fluid, an accumulator must be provided to remove the pulsation.</p>
<p class="size15 mb10">5. Be careful not to apply excessive stress on the Flowsensor / Flowmeter during installation.</p>
<p class="size15 mb10">6. Make sure to provide thermal insulator at places subject to freezing in winter. When leakage occurs due to half frozen fluid, accuracy is adversely affected.</p>
<p class="size15 mb10">7. Do not expose/install the Flowsensor / Flowmeter under direct sunshine.</p>
<p class="size15 mb10">8. The measuring range, operating pressure and operating temperature are indicated on the plate on the side of the Flowsensor / Flowmeter. Observe these conditions for optimum performance of the Flowsensor / Flowmeter.</p>
<p class="size15 mb10">9. Avoid locating the Flowsensor / Flowmeter at places subject to excessive pressure and stress such as water hammer by operating components.</p>
<p class="size15 mb10">10. When air enters the Flowsensor / Flowmeter, measurement accuracy is influenced. Always operate the Flowsensor / Flowmeter chamber full of fluid. To maintain high accuracy, avoid mixture of air to the fluid.</p>
<p class="size15 mb10">11. Avoid placing a strong magnetic material or magnetic field near the Flowsensor / Flowmeter.</p>
<p class="size15 mb35">12. Installation position is flexible except those shown in figures on the upper right. However, it is recommended to install the Flowsensor / Flowmeter at the standard position whenever possible. For types ND 05-TATAAA, ND10-TATAAA, NW05-TTN, NW10-TTN, installation must be at standard positions.</p>
<p class="size15 bold">Standard mounting position</p>
<p class="size15 bold"><img loading="lazy" decoding="async" class="alignnone wp-image-809 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2.png" sizes="(max-width: 531px) 100vw, 531px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2.png 531w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2-300x163.png 300w" alt="sample2" width="531" height="288" /></p>
<p class="size15 bold">CONNECTION (WIRING)</p>
<p class="size15 bold"><img loading="lazy" decoding="async" class="alignnone wp-image-810 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3.png" sizes="(max-width: 672px) 100vw, 672px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3.png 672w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3-300x224.png 300w" alt="sample3" width="672" height="501" /></p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Measurable fluids and parts materials</h1>
<p class="size15 bold">MEASURABLE FLUIDS</p>
<p class="size15 mb20">１．Fluid which done not corrode materials that contact the fluid. ２．Viscosity of the fluid to be measured is between 0.5 and 1.5cp. ３．No slurry is contained. ４．Particles attracted by magnetic power such as iron, is contained in the fluid. (All of the above 1-4 must be satisfied.)</p>
<p class="size15 bold">LIST OF MATERIALS THAT CONTACT FLUIDS DIRECTLY</p>
<p class="size15 mb20">The table below shows components and materials of the standard type Flowsensor / Flowmeter used in portions that come into direct contact with the fluid.</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Parts name</th>
<th colspan="6">Model</th>
</tr>
<tr>
<th>ND05-PATAAC NW05-PTN NW05-PTP</th>
<th>ND05-NATAAC NW05-NTN NW05-NTP</th>
<th>ND05-TATAAA NW05-TTN NW05-TTP ND10-TATAAA NW10-TTN NW10-TTP</th>
<th>ND10-PATAAA NW10-PTN NW10-PTP</th>
<th>ND20-PATAAA NW20-PTN NW20-PTP</th>
<th>ND10-NATAAA NW10-NTN NW10-NTP ND20-NATAAA NW20-NTN NW20-NTP</th>
</tr>
<tr>
<th>Lower casing Upper casing Regulator</th>
<td>PP</td>
<td>Denatured PPO</td>
<td rowspan="3">ETFE</td>
<td>PP</td>
<td>PP</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane-wheel</th>
<td>POM</td>
<td>POM</td>
<td>POM</td>
<td>POM</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>PA</td>
<td>SUS304</td>
<td>PA</td>
<td>SUS304</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>FKM</td>
<td>NBR</td>
<td>FKM</td>
<td>FKM</td>
<td>FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Ba-Fe</td>
<td>Ba-Fe</td>
<td>Ba-Fe</td>
</tr>
<tr>
<th>Measurable fluid</th>
<td>Water, Chemical fluid (Weak corrosion resistance)</td>
<td>Water, Warm Water</td>
<td>Chemical fluid</td>
<td colspan="2">Water, Chemical Fluid (Weak corrosion resistance)</td>
<td>Water, Warm Water</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Material Code</p>
<p class="size15 mb20">・Ba-Fe: Barium-Ferrite ・ETFE: Ethylene-tetrafluoro ethylene ・FKM: Fluoro Rubber ・NBR: Acrylonitrile-butadiene rubber ・PA: Polyamide ・POM: Polyacetal or Polyoxymethylene ・PP: Polypropylene ・PPO: Polyphenylene oxide ・SUS304: Stainless steel</p>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lưu lượng kế Aichi Tokei NW10-NTN</title>
		<link>https://congcusanxuat.vn/san-pham/luu-luong-ke-aichi-tokei-nw10-ntn/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:22:57 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12397</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/nwnw-p-series/">Lưu lượng kế Aichi Tokei NW10-NTN</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Feature</h1>
<p class="size15 mb20">・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the vane wheel type measuring principle ・Measurement of various liquids ・Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) ・Value holding function for Instantaneous Flow-Rate indication ・Pulse output function (Option)</p>
<p class="size15 mb20">Model NW (Local display type) Model NW-P (With pulse output)</p>
<p class="size15 bold">Enhanced basic functions, user friendliness and cost efficiency are the key points</p>
<p class="size15 mb20">ND series offers high accuracy measurement of not only cold and warm water but also pure water, chemical fluids, etc. It is light-weighted compact body and is compatible with various kinds of fluids with the carefully selected casing materials such as PP, ETFE, PPO, etc., and with the highly sensitive magnetic sensor of our own development. This series is therefore widely applicable for various flow measurements and its control and monitoring as well.</p>
<p class="size15 bold">Flowsensor Applications</p>
<p class="size15 mb20">・To control of warm water temperature ・To constantly supply water and warm water ・To monitor coolant, etc. ・To proportionally inject chemical fluids ・To control pressure loss of filters</p>
</section>
<section id="overview" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW05-NTN</th>
<th>NW05-PTN</th>
<th>NW05-TTN</th>
<th>NW10-NTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW05-NTP</th>
<th>NW05-PTP</th>
<th>NW05-TTP</th>
<th>NW10-NTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td colspan="3">0.3 – 3L/min</td>
<td>1.5 – 20L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="3">±2%RS±0.05L/min</td>
<td>±2% RS±0.2L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td colspan="3">Not more than 12kPa (At the time of 3L/min)</td>
<td>Not more than 20kPa (At the time of 20L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa・s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not morethan 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="3">10mL/p</td>
<td>1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="3">0.05L/min</td>
<td>0.2L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="3">00.00L/min</td>
<td>000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="3">000000.00L</td>
<td>0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="4">R1/2</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 280g</td>
<td>Approx. 250g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>Denatured PPO</td>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane wheel</th>
<td colspan="2">POM</td>
<td>ETFE</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>PA</td>
<td>ETFE</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>NBR</td>
<td colspan="2">FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td colspan="3">Sa-Co *1</td>
<td>Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW10-PTN</th>
<th>NW10-TTN</th>
<th>NW20-NTN</th>
<th>NW20-PTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW10-PTP</th>
<th>NW10-TTP</th>
<th>NW20-NTP</th>
<th>NW20-PTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td>1.5-20L/min</td>
<td>1.0-10L/min</td>
<td colspan="2">3.0-60L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="2">±2%RS±0.2L/min</td>
<td colspan="2">±2% RS±0.5L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td>Not more than 20kPa (At the time of 20L/min)</td>
<td>Not more than 15kPa (At the time of 10L/min)</td>
<td colspan="2">Not more than 60kPa (At the time of 60L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa·s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="4">1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="2">0.2L/min</td>
<td colspan="2">0.5L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="4">000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="4">0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="2">R1/2</td>
<td colspan="2">R3/4</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 250g</td>
<td>Approx. 500g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
<td>PP</td>
</tr>
<tr>
<th>Vane wheel</th>
<td>POM</td>
<td>ETFE</td>
<td colspan="2">POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>ETFE</td>
<td colspan="2">SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td colspan="2">FKM</td>
<td>NBR</td>
<td>FKM</td>
</tr>
<tr>
<th>Magnet</th>
<td>Ba-Fe</td>
<td>Sa-Co *1</td>
<td colspan="2">Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<p class="size13">Any installation position other than the standard installation position is not available for NW05-TTN, NW05-TTP, NW10-TTN, and NW10-TTP. *1: The magnet does not touch liquid.</p>
</section>
<section id="dimensions" class="product_section_wrap">
<h1 class="section_title">Dimensions</h1>
<div class="mb10">
<table>
<tbody>
<tr>
<th>Mode</th>
<th>NW05</th>
<th>NW10</th>
<th>NW20</th>
</tr>
<tr>
<th>A(mm)</th>
<td>80</td>
<td>80</td>
<td>110</td>
</tr>
<tr>
<th>B(mm)</th>
<td>87</td>
<td>87</td>
<td>105.5</td>
</tr>
<tr>
<th>C(mm)</th>
<td>52</td>
<td>52</td>
<td>74</td>
</tr>
<tr>
<th>D(mm)</th>
<td>11</td>
<td>11</td>
<td>16</td>
</tr>
<tr>
<th>E(mm)</th>
<td>25</td>
<td>25</td>
<td>35.5</td>
</tr>
</tbody>
</table>
</div>
<div class="mb35">
<p><img loading="lazy" decoding="async" class="alignnone wp-image-803 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/nw_glaf.gif" alt="nw_glaf" width="473" height="249" /></p>
<p class="size15 bold">Standard installation position</p>
<p class="size15">The standard installation position is that the display is facing upwards. * The display is able to be revolved.</p>
<div class="mb35"><img loading="lazy" decoding="async" class="alignnone wp-image-804 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/nw_position.gif" alt="nw_position" width="300" height="235" /></div>
<p class="size15 bold">Materials -Abbreviations</p>
<table>
<tbody>
<tr>
<th>Denatured PPO</th>
<td>Denatured Polyphenylene oxide</td>
</tr>
<tr>
<th>PP</th>
<td>Polypropylene</td>
</tr>
<tr>
<th>ETFE</th>
<td>Ethylene-tetrafiuoro ethylene</td>
</tr>
<tr>
<th>POM</th>
<td>Polyacetal or Polyoxymethylene</td>
</tr>
<tr>
<th>SUS304</th>
<td>Stainless steel 304</td>
</tr>
<tr>
<th>PA</th>
<td>Polyamide</td>
</tr>
<tr>
<th>NBR</th>
<td>Acrylonitrile-Butadiene Rubber</td>
</tr>
<tr>
<th>FKM</th>
<td>Fluoro Rubber</td>
</tr>
<tr>
<th>Sa-Co</th>
<td>Samarium-Cobalt</td>
</tr>
<tr>
<th>Ba-Fe</th>
<td>Barium-ferrite</td>
</tr>
</tbody>
</table>
</div>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Handling Instructions</h1>
<p class="size15 mb20">Observe the following handling instructions and precautions to obtain maximum performance of the Flowsensor / Flowmeter.</p>
<p class="size15 bold">CAUTIONS IN MOUNTING</p>
<p class="size15 mb10">1. The flowing direction of the fluid, when mounting, must be matched to the arrow mark on the case that indicates the direction of flow.</p>
<p class="size15 mb10">2. A straight pipe with uniform inner diameter must be connected to the inlet. Accuracy is adversely affected if the pipe is bent or the inner diameter is uneven.</p>
<p class="size15 mb10">3. The inner diameter of the inlet pipe must be greater than the nozzle diameter of the Flowsensor / Flowmeter.</p>
<div class="mb20">
<table>
<tbody>
<tr>
<th>Type</th>
<th>Inner D, of inlet pipe</th>
<th>Length of straight pipe at inlet</th>
</tr>
<tr>
<th>ND05,NW05</th>
<td>5.5 mm or greater</td>
<td>Greater than 50 mm from the end of the Flowsensor / Flowmeter</td>
</tr>
<tr>
<th>ND10,NW10</th>
<td>10.5 mm or greater</td>
<td rowspan="2">Greater than 100 mm from the end of the Flowsensor / Flowmeter</td>
</tr>
<tr>
<th>ND20,NW20</th>
<td>15.5 mm or greater</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 mb10">4. If pulsation occurs in the flow of the fluid, measurement accuracy is adversely affected. When a pump is used to circulate the fluid, an accumulator must be provided to remove the pulsation.</p>
<p class="size15 mb10">5. Be careful not to apply excessive stress on the Flowsensor / Flowmeter during installation.</p>
<p class="size15 mb10">6. Make sure to provide thermal insulator at places subject to freezing in winter. When leakage occurs due to half frozen fluid, accuracy is adversely affected.</p>
<p class="size15 mb10">7. Do not expose/install the Flowsensor / Flowmeter under direct sunshine.</p>
<p class="size15 mb10">8. The measuring range, operating pressure and operating temperature are indicated on the plate on the side of the Flowsensor / Flowmeter. Observe these conditions for optimum performance of the Flowsensor / Flowmeter.</p>
<p class="size15 mb10">9. Avoid locating the Flowsensor / Flowmeter at places subject to excessive pressure and stress such as water hammer by operating components.</p>
<p class="size15 mb10">10. When air enters the Flowsensor / Flowmeter, measurement accuracy is influenced. Always operate the Flowsensor / Flowmeter chamber full of fluid. To maintain high accuracy, avoid mixture of air to the fluid.</p>
<p class="size15 mb10">11. Avoid placing a strong magnetic material or magnetic field near the Flowsensor / Flowmeter.</p>
<p class="size15 mb35">12. Installation position is flexible except those shown in figures on the upper right. However, it is recommended to install the Flowsensor / Flowmeter at the standard position whenever possible. For types ND 05-TATAAA, ND10-TATAAA, NW05-TTN, NW10-TTN, installation must be at standard positions.</p>
<p class="size15 bold">Standard mounting position</p>
<p class="size15 bold"><img loading="lazy" decoding="async" class="alignnone wp-image-809 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2.png" sizes="(max-width: 531px) 100vw, 531px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2.png 531w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample2-300x163.png 300w" alt="sample2" width="531" height="288" /></p>
<p class="size15 bold">CONNECTION (WIRING)</p>
<p class="size15 bold"><img loading="lazy" decoding="async" class="alignnone wp-image-810 size-full" src="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3.png" sizes="(max-width: 672px) 100vw, 672px" srcset="https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3.png 672w, https://www.aichitokei.net/admin/wp-content/uploads/2015/07/sample3-300x224.png 300w" alt="sample3" width="672" height="501" /></p>
</section>
<section class="product_section_wrap">
<h1 class="section_title">Measurable fluids and parts materials</h1>
<p class="size15 bold">MEASURABLE FLUIDS</p>
<p class="size15 mb20">１．Fluid which done not corrode materials that contact the fluid. ２．Viscosity of the fluid to be measured is between 0.5 and 1.5cp. ３．No slurry is contained. ４．Particles attracted by magnetic power such as iron, is contained in the fluid. (All of the above 1-4 must be satisfied.)</p>
<p class="size15 bold">LIST OF MATERIALS THAT CONTACT FLUIDS DIRECTLY</p>
<p class="size15 mb20">The table below shows components and materials of the standard type Flowsensor / Flowmeter used in portions that come into direct contact with the fluid.</p>
<div class="mb35">
<table>
<tbody>
<tr>
<th rowspan="2">Parts name</th>
<th colspan="6">Model</th>
</tr>
<tr>
<th>ND05-PATAAC NW05-PTN NW05-PTP</th>
<th>ND05-NATAAC NW05-NTN NW05-NTP</th>
<th>ND05-TATAAA NW05-TTN NW05-TTP ND10-TATAAA NW10-TTN NW10-TTP</th>
<th>ND10-PATAAA NW10-PTN NW10-PTP</th>
<th>ND20-PATAAA NW20-PTN NW20-PTP</th>
<th>ND10-NATAAA NW10-NTN NW10-NTP ND20-NATAAA NW20-NTN NW20-NTP</th>
</tr>
<tr>
<th>Lower casing Upper casing Regulator</th>
<td>PP</td>
<td>Denatured PPO</td>
<td rowspan="3">ETFE</td>
<td>PP</td>
<td>PP</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane-wheel</th>
<td>POM</td>
<td>POM</td>
<td>POM</td>
<td>POM</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>PA</td>
<td>SUS304</td>
<td>PA</td>
<td>SUS304</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>FKM</td>
<td>NBR</td>
<td>FKM</td>
<td>FKM</td>
<td>FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Samarium cobalt (No contact with fluid)</td>
<td>Ba-Fe</td>
<td>Ba-Fe</td>
<td>Ba-Fe</td>
</tr>
<tr>
<th>Measurable fluid</th>
<td>Water, Chemical fluid (Weak corrosion resistance)</td>
<td>Water, Warm Water</td>
<td>Chemical fluid</td>
<td colspan="2">Water, Chemical Fluid (Weak corrosion resistance)</td>
<td>Water, Warm Water</td>
</tr>
</tbody>
</table>
</div>
<p class="size15 bold">Material Code</p>
<p class="size15 mb20">・Ba-Fe: Barium-Ferrite ・ETFE: Ethylene-tetrafluoro ethylene ・FKM: Fluoro Rubber ・NBR: Acrylonitrile-butadiene rubber ・PA: Polyamide ・POM: Polyacetal or Polyoxymethylene ・PP: Polypropylene ・PPO: Polyphenylene oxide ・SUS304: Stainless steel</p>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lưu lượng kế Aichi Tokei NW05-PTN</title>
		<link>https://congcusanxuat.vn/san-pham/luu-luong-ke-aichi-tokei-nw05-ptn/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:20:41 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12396</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/nwnw-p-series/">Lưu lượng kế Aichi Tokei NW05-PTN</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Feature</h1>
<p class="size15 mb20">・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the vane wheel type measuring principle ・Measurement of various liquids ・Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) ・Value holding function for Instantaneous Flow-Rate indication ・Pulse output function (Option)</p>
<p class="size15 mb20">Model NW (Local display type) Model NW-P (With pulse output)</p>
<p class="size15 bold">Enhanced basic functions, user friendliness and cost efficiency are the key points</p>
<p class="size15 mb20">ND series offers high accuracy measurement of not only cold and warm water but also pure water, chemical fluids, etc. It is light-weighted compact body and is compatible with various kinds of fluids with the carefully selected casing materials such as PP, ETFE, PPO, etc., and with the highly sensitive magnetic sensor of our own development. This series is therefore widely applicable for various flow measurements and its control and monitoring as well.</p>
<p class="size15 bold">Flowsensor Applications</p>
<p class="size15 mb20">・To control of warm water temperature ・To constantly supply water and warm water ・To monitor coolant, etc. ・To proportionally inject chemical fluids ・To control pressure loss of filters</p>
</section>
<section id="overview" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW05-NTN</th>
<th>NW05-PTN</th>
<th>NW05-TTN</th>
<th>NW10-NTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW05-NTP</th>
<th>NW05-PTP</th>
<th>NW05-TTP</th>
<th>NW10-NTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td colspan="3">0.3 – 3L/min</td>
<td>1.5 – 20L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="3">±2%RS±0.05L/min</td>
<td>±2% RS±0.2L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td colspan="3">Not more than 12kPa (At the time of 3L/min)</td>
<td>Not more than 20kPa (At the time of 20L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa・s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not morethan 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="3">10mL/p</td>
<td>1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="3">0.05L/min</td>
<td>0.2L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="3">00.00L/min</td>
<td>000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="3">000000.00L</td>
<td>0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="4">R1/2</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 280g</td>
<td>Approx. 250g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>Denatured PPO</td>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane wheel</th>
<td colspan="2">POM</td>
<td>ETFE</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>PA</td>
<td>ETFE</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>NBR</td>
<td colspan="2">FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td colspan="3">Sa-Co *1</td>
<td>Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW10-PTN</th>
<th>NW10-TTN</th>
<th>NW20-NTN</th>
<th>NW20-PTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW10-PTP</th>
<th>NW10-TTP</th>
<th>NW20-NTP</th>
<th>NW20-PTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td>1.5-20L/min</td>
<td>1.0-10L/min</td>
<td colspan="2">3.0-60L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="2">±2%RS±0.2L/min</td>
<td colspan="2">±2% RS±0.5L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td>Not more than 20kPa (At the time of 20L/min)</td>
<td>Not more than 15kPa (At the time of 10L/min)</td>
<td colspan="2">Not more than 60kPa (At the time of 60L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa·s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="4">1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="2">0.2L/min</td>
<td colspan="2">0.5L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="4">000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="4">0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="2">R1/2</td>
<td colspan="2">R3/4</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 250g</td>
<td>Approx. 500g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
<td>PP</td>
</tr>
<tr>
<th>Vane wheel</th>
<td>POM</td>
<td>ETFE</td>
<td colspan="2">POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>ETFE</td>
<td colspan="2">SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td colspan="2">FKM</td>
<td>NBR</td>
<td>FKM</td>
</tr>
<tr>
<th>Magnet</th>
<td>Ba-Fe</td>
<td>Sa-Co *1</td>
<td colspan="2">Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
</section>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lưu lượng kế Aichi Tokei NW20-PTN</title>
		<link>https://congcusanxuat.vn/san-pham/luu-luong-ke-aichi-tokei-nw20-ptn/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 04:18:42 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12393</guid>

					<description><![CDATA[<a href="https://www.aichitokei.net/products/nwnw-p-series/">Lưu lượng kế Aichi Tokei NW20-PTN</a>]]></description>
										<content:encoded><![CDATA[<section id="feature" class="product_section_wrap active">
<h1 class="section_title">Feature</h1>
<p class="size15 mb20">・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the vane wheel type measuring principle ・Measurement of various liquids ・Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) ・Value holding function for Instantaneous Flow-Rate indication ・Pulse output function (Option)</p>
<p class="size15 mb20">Model NW (Local display type) Model NW-P (With pulse output)</p>
<p class="size15 bold">Enhanced basic functions, user friendliness and cost efficiency are the key points</p>
<p class="size15 mb20">ND series offers high accuracy measurement of not only cold and warm water but also pure water, chemical fluids, etc. It is light-weighted compact body and is compatible with various kinds of fluids with the carefully selected casing materials such as PP, ETFE, PPO, etc., and with the highly sensitive magnetic sensor of our own development. This series is therefore widely applicable for various flow measurements and its control and monitoring as well.</p>
<p class="size15 bold">Flowsensor Applications</p>
<p class="size15 mb20">・To control of warm water temperature ・To constantly supply water and warm water ・To monitor coolant, etc. ・To proportionally inject chemical fluids ・To control pressure loss of filters</p>
</section>
<section id="overview" class="product_section_wrap">
<h1 class="section_title">Specifications</h1>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW05-NTN</th>
<th>NW05-PTN</th>
<th>NW05-TTN</th>
<th>NW10-NTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW05-NTP</th>
<th>NW05-PTP</th>
<th>NW05-TTP</th>
<th>NW10-NTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td colspan="3">0.3 – 3L/min</td>
<td>1.5 – 20L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="3">±2%RS±0.05L/min</td>
<td>±2% RS±0.2L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td colspan="3">Not more than 12kPa (At the time of 3L/min)</td>
<td>Not more than 20kPa (At the time of 20L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa・s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not morethan 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="3">10mL/p</td>
<td>1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="3">0.05L/min</td>
<td>0.2L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="3">00.00L/min</td>
<td>000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="3">000000.00L</td>
<td>0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="4">R1/2</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 280g</td>
<td>Approx. 250g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>Denatured PPO</td>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
</tr>
<tr>
<th>Vane wheel</th>
<td colspan="2">POM</td>
<td>ETFE</td>
<td>POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>PA</td>
<td>ETFE</td>
<td>SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td>NBR</td>
<td colspan="2">FKM</td>
<td>NBR</td>
</tr>
<tr>
<th>Magnet</th>
<td colspan="3">Sa-Co *1</td>
<td>Ba-Fe</td>
</tr>
</tbody>
</table>
</div>
<div class="mb20">
<table>
<tbody>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter NW Type</th>
<th>NW10-PTN</th>
<th>NW10-TTN</th>
<th>NW20-NTN</th>
<th>NW20-PTN</th>
</tr>
<tr>
<th colspan="3">Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P Type</th>
<th>NW10-PTP</th>
<th>NW10-TTP</th>
<th>NW20-NTP</th>
<th>NW20-PTP</th>
</tr>
<tr>
<th colspan="3">Flow-rate range (m3/h)</th>
<td>1.5-20L/min</td>
<td>1.0-10L/min</td>
<td colspan="2">3.0-60L/min</td>
</tr>
<tr>
<th rowspan="2">Accuracy</th>
<th colspan="2">Flow-rate indication</th>
<td colspan="2">±2%RS±0.2L/min</td>
<td colspan="2">±2% RS±0.5L/min</td>
</tr>
<tr>
<th colspan="2">Volume indication</th>
<td colspan="4">±2%RS (with the standard installation position)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Various liquids (Please select with reference to the following major materials of the liquid-touching materials)</td>
</tr>
<tr>
<th colspan="3">Max. Working Pressure</th>
<td colspan="4">1MPa (at the time of fluid temperature of 20°C)</td>
</tr>
<tr>
<th colspan="3">Pressure Drop</th>
<td>Not more than 20kPa (At the time of 20L/min)</td>
<td>Not more than 15kPa (At the time of 10L/min)</td>
<td colspan="2">Not more than 60kPa (At the time of 60L/min)</td>
</tr>
<tr>
<th colspan="3">Fluid viscosity range</th>
<td colspan="4">0.5-1.5mPa·s</td>
</tr>
<tr>
<th colspan="3">Fluid temperature range</th>
<td colspan="4">0±60°C</td>
</tr>
<tr>
<th colspan="3">Ambient temperature range</th>
<td colspan="4">0±60°C 35-85%RH(Dew condensation must be avoided)</td>
</tr>
<tr>
<th colspan="3">Output signal (for NW-P)</th>
<td colspan="4">Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA)</td>
</tr>
<tr>
<th colspan="3">Pulse unit (for NW-P)</th>
<td colspan="4">1L/p</td>
</tr>
<tr>
<th rowspan="3">LCD</th>
<th rowspan="2">Flow-rate</th>
<th>Smallest Scale</th>
<td colspan="2">0.2L/min</td>
<td colspan="2">0.5L/min</td>
</tr>
<tr>
<th>Display digits</th>
<td colspan="4">000.0L/min</td>
</tr>
<tr>
<th>Volume</th>
<th>Display digits</th>
<td colspan="4">0000000.0L</td>
</tr>
<tr>
<th colspan="3">Power supply</th>
<td colspan="4">Built-in lithium battery (Battery life 4 years. Not replaceable.)</td>
</tr>
<tr>
<th colspan="3">Measurable fluids</th>
<td colspan="4">Refer to “MEASURABLE FLUID AND PARTS MATERIALS”</td>
</tr>
<tr>
<th colspan="3">Structure</th>
<td colspan="4">IP64 equivalent, Indoor installation</td>
</tr>
<tr>
<th colspan="3">Connection</th>
<td colspan="2">R1/2</td>
<td colspan="2">R3/4</td>
</tr>
<tr>
<th colspan="3">Meter Weight</th>
<td colspan="3">Approx. 250g</td>
<td>Approx. 500g</td>
</tr>
<tr>
<th colspan="2" rowspan="5">Major materials of the liquid touching parts</th>
<th>Casing</th>
<td>PP</td>
<td>ETFE</td>
<td>Denatured PPO</td>
<td>PP</td>
</tr>
<tr>
<th>Vane wheel</th>
<td>POM</td>
<td>ETFE</td>
<td colspan="2">POM</td>
</tr>
<tr>
<th>Pivot</th>
<td>SUS304</td>
<td>ETFE</td>
<td colspan="2">SUS304</td>
</tr>
<tr>
<th>O-ring</th>
<td colspan="2">FKM</td>
<td>NBR</td>
<td>FKM</td>
</tr>
<tr>
<th>Magnet</th>
<td>Ba-Fe</td>
<td>Sa-Co *1</td>
<td colspan="2">Ba-Fe</td>
</tr>