<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SKF &#8211; Hà Sơn</title>
	<atom:link href="https://congcusanxuat.vn/danh-muc-san-pham/nha-san-xuat/skf/feed/" rel="self" type="application/rss+xml" />
	<link>https://congcusanxuat.vn</link>
	<description>Công cụ sản xuất</description>
	<lastBuildDate>Tue, 07 Sep 2021 07:02:45 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.8</generator>

<image>
	<url>https://congcusanxuat.vn/wp-content/uploads/2020/03/cropped-logo2-2-32x32.gif</url>
	<title>SKF &#8211; Hà Sơn</title>
	<link>https://congcusanxuat.vn</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Bộ bơm dầu SKF MKU5-BW3-20003J</title>
		<link>https://congcusanxuat.vn/san-pham/bo-bom-dau-skf-mku5-bw3-20003j/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 07:02:45 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12444</guid>

					<description><![CDATA[<a href="https://www.skf.com/group/products/lubrication-management/system-components/pumps-and-pump-units/mkx-mku-mkf-mkl">Bộ bơm dầu SKF MKU5-BW3-20003J</a>]]></description>
										<content:encoded><![CDATA[<header id="header" role="banner">
<section>
<div class="container">
<div class="row">
<div id="cid-469549" class="col-md-12">
<div class="row flex-wrap-reverse">
<div class="col-sm-12 col-md-7 offset-md-5 title">
<h1>Electrically operated gear pump unit series MKx (MKF, MKL, MKU)</h1>
</div>
</div>
</div>
</div>
</div>
</section>
</header>
<p><main id="main" role="main"></p>
<section class="sections">
<div>
<div class="container">
<div class="row">
<div id="cid-486183" class="col-md-12 space-between">
<div class="product-info row">
<div class="col-sm-12 col-lg-5">
<div class="carousel slide" tabindex="0">
<ol class="carousel-indicators">
<li class=""></li>
<li class="active"></li>
<li class=""></li>
<li class=""></li>
</ol>
<div class="carousel-inner">
<div class="item active"><img decoding="async" class="d-block w-100" src="https://www.skf.com/binaries/pub12/Images/0901d196800d722a-MKU2-BW3-20003-428_tcm_12-21261.png" alt="MKU Compact Units for Oil " /></div>
</div>
<p><span><span class="sr-only">Previous</span></span><span><span class="sr-only">Next</span></span></div>
</div>
<div class="content-area col-sm-12 col-lg-7">
<div class="description">
<div class="content text-darker-green-grey">
<div id="rich-text-div">
<h3>For use in single-line or oil and air lubrication systems</h3>
<p>MKx gear pump units include a pressure-regulating valve and pressure-relief valve. Electrical pressure monitoring is performed by an integrated pressure switch, and fill-level monitoring also is possible. These units are controlled externally via the machine control system or an integrated control unit. Also, MKx units can be supplied with a pushbutton to activate interim lubrication at any time. Main functions are integrated into the lid, and a plastic cap protects the electrical components from contaminants such as dirt and dust.</p>
<p><strong>MKU</strong> units supply oil with a viscosity of 20 to 1 500 mm²/s in single-line lubrication systems. These units can be supplied with an optional pressure gauge for visual monitoring of pressure changes in the main line.</p>
<p><strong>MKF</strong> units are used in single-line systems to supply fluid greases NLGI 000 and 00.</p>
<p><strong>MKL</strong> units supply an oil and air mixture in oil and air lubrication systems.</p>
</div>
</div>
</div>
<div class="d-flex flex-wrap button-wrapper"><span>FIND A DISTRIBUTOR</span></div>
<div class="columns">
<div class="column-one">
<div class="content text-darker-green-grey">
<div id="rich-text-div">
<p class="small-capital-heading">Features and benefits</p>
<ul>
<li>Integrated pressure-limitation and pressure-relief valve</li>
<li>Optional: electrical pressure switch, pressure gauge, float switch</li>
<li>External control via SPS or by means of internal control unit possible</li>
<li>All important functions integrated into the lid</li>
<li>Modular construction</li>
</ul>
</div>
</div>
</div>
<div class="column-two">
<div class="content text-darker-green-grey">
<div id="rich-text-div">
<p class="small-capital-heading">applications</p>
<ul>
<li>Material handling</li>
<li>Automotives</li>
<li>Machine tool</li>
<li>Printing and finishing</li>
<li>Industrial assembly and automation</li>
<li>Textiles</li>
</ul>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
<section class="sections">
<div>
<div id="cid-486185" class="bg-off-white">
<div class="container">
<div class="content">
<div class="shortcuts">
<div class="shortcut"><span>TECHNICAL DATA</span></div>
<div class="shortcut"><span>ORDER INFORMATION</span></div>
<div class="shortcut"><span>CAD DOWNLOADS</span></div>
<div class="shortcut"><span>RELATED DOWNLOADS AND PRODUCTS</span></div>
<div class="shortcut"><span>MORE LUBRICATION TOOLS, SERVICES AND DOWNLOADS</span></div>
<div class="shortcut"><span>MORE PRODUCTS</span></div>
<div class="progress-container"></div>
</div>
</div>
</div>
</div>
</div>
</section>
<section class="sections">
<div>
<div class="container">
<div class="row">
<div id="cid-483307" class="body-text-main col-md-8 space-between">
<div class="body-text-main">
<div class="body">
<div class="content text-darker-green-grey">
<div id="rich-text-div">
<table class="no-colors" title="Technical data" border="1" width="100%" cellspacing="1" cellpadding="1">
<caption>TECHNICAL DATA</caption>
<colgroup>
<col width="40%" valign="top" />
<col width="30%" valign="top" />
<col width="30%" valign="top" /></colgroup>
<tbody>
<tr>
<td>Function principle</td>
<td colspan="2">Electrically operated gear pump</td>
</tr>
<tr>
<td colspan="3">Lubricant</td>
</tr>
<tr>
<td><strong>MKU; MKL</strong></td>
<td colspan="2">mineral oil or synthetic oil, 20-1500 mm²/s</td>
</tr>
<tr>
<td><strong>MKF</strong></td>
<td colspan="2">fluid grease NLGI 000 or 00</td>
</tr>
<tr>
<td>Number of lubricant outlets</td>
<td colspan="2">1</td>
</tr>
<tr>
<td>Metering quantity</td>
<td>100; 200; 500 cm³/min</td>
<td><em>6; 12; 31 in³/min</em></td>
</tr>
<tr>
<td>Operating temperature</td>
<td>+10 to 40 °C</td>
<td><em>+50 to 104 °F</em></td>
</tr>
<tr>
<td>Operating pressure</td>
<td>max. 30 bar</td>
<td><em>435 psi</em></td>
</tr>
<tr>
<td>Capacity of the reservoir</td>
<td>2,0; 3,0 and 6,0 l</td>
<td><em>0.5, 0.8 and 1.6 gal</em></td>
</tr>
<tr>
<td>Material (reservoir)</td>
<td colspan="2">plastic, metal</td>
</tr>
<tr>
<td>Connection outlet</td>
<td colspan="2">G 1/4</td>
</tr>
<tr>
<td>Protection class</td>
<td colspan="2">IP 54</td>
</tr>
<tr>
<td>Voltage</td>
<td colspan="2">24 V DC<br />
115 or 230 V AC; 50/60 Hz</td>
</tr>
<tr>
<td colspan="3">Dimensions depending on reservoir</td>
</tr>
<tr>
<td>2 l; <em>0.5 gal</em> plastic</td>
<td>204 × 130 × 298 mm</td>
<td><em>8 × 5.2 × 11.7 in</em></td>
</tr>
<tr>
<td>3 l; <em>0.8 gal</em> plastic</td>
<td>286 × 132 × 298 mm</td>
<td><em>11.3 × 5.2 × 11.7 in</em></td>
</tr>
<tr>
<td>3 l; <em>0.8 gal</em> metal</td>
<td>286 × 132 × 313 mm</td>
<td><em>11.3 × 5.2 × 12.3 in</em></td>
</tr>
<tr>
<td>6 l; <em>1,5 gal</em> plastic</td>
<td>290 × 178 × 334 mm</td>
<td><em>11.4 × 7 × 13.2 in</em></td>
</tr>
<tr>
<td>Mounting position</td>
<td colspan="2">vertical</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
<section class="sections">
<div>
<div class="container">
<div class="row">
<div id="cid-483306" class="body-text-main col-md-8 space-between">
<div class="body-text-main">
<div class="body">
<div class="content text-darker-green-grey">
<div id="rich-text-div">
<table class="no-colors" title="Technical data" border="1" width="100%" cellspacing="1" cellpadding="1">
<caption>ORDER EXAMPLE</caption>
<colgroup>
<col width="40%" valign="top" />
<col width="60%" valign="top" /></colgroup>
<tbody>
<tr>
<td colspan="2">The product can be configured using a configuration code. The order example shows one possible part number and its explanation.</td>
</tr>
<tr>
<td><strong>MKU1-11AC10000+924</strong></td>
<td>
<ul>
<li>Gear pump unit for oil Delivery rate 0,1 l/min 1st generation</li>
<li>2 l plastic reservoir</li>
<li>No control, with terminal strip</li>
<li>NC fill-level switch</li>
<li>NO pressure switch</li>
<li>With pressure gauge</li>
<li>2 cable fittings</li>
<li>Voltage 24 V DC</li>
</ul>
</td>
</tr>
<tr>
<td><strong>MKF1-11AC10000+924</strong></td>
<td>
<ul>
<li>Gear pump unit for fluid grease</li>
<li>Delivery rate 0,1 l/min</li>
<li>1st generation</li>
<li>2 l plastic reservoir</li>
<li>No control, with terminal strip</li>
<li>NC fill-level switch</li>
<li>NO pressure switch</li>
<li>With pressure gauge</li>
<li>2 cable fittings</li>
<li>Voltage 24 V DC</li>
</ul>
</td>
</tr>
<tr>
<td colspan="2">You can configure the product using the CAD configurator below. This will give you a specific order number.</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</section>
<p></main></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Khóa hãm SKF KMTA5</title>
		<link>https://congcusanxuat.vn/san-pham/khoa-ham-skf-kmta5/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 06:56:17 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12441</guid>

					<description><![CDATA[<a href="https://www.skf.com/group/products/super-precision-bearings/precision-lock-nuts/productid-KMTA%205">Khóa hãm SKF KMTA5 </a>]]></description>
										<content:encoded><![CDATA[<h2 class="headline">Technical specification</h2>
<div class="toolbelt">
<div class="toolbelt-options toolbelt-options-technical-spec">
<div class="units-wrapper"><span class="units">Display in:</span><span class="systems-radio"><label class="radio-inline active"><i class="far fa-dot-circle"></i>Metric</label><label class="radio-inline"><i class="far fa-circle"></i>Imperial</label></span></div>
<div class="tech-spec-link"><span><i class="icon-link-download"></i>Technical Specification PDF</span></div>
</div>
</div>
<div class="content-block">
<div class="row">
<div class="col-sm-12 col-md-6 spec-images"><img decoding="async" src="https://www.skf.com/webpim/0901d19680390d02/0901d19680390d02.svg" alt="Dimensions - KMTA 5" /></div>
<div class="col-sm-12 col-md-6">
<h3 class="pb-4 pdf-title">DIMENSIONS</h3>
<table class="table">
<tbody>
<tr>
<th scope="row">G</th>
<td class="td-width">
<div>M 25&#215;1.5</div>
</td>
<td>Thread</td>
</tr>
<tr>
<th scope="row">d<sub>1</sub></th>
<td class="td-width">
<div>35 mm</div>
</td>
<td>Outside diameter locating side face</td>
</tr>
<tr>
<th scope="row">B</th>
<td class="td-width">
<div>20 mm</div>
</td>
<td>Width</td>
</tr>
<tr>
<th scope="row">d<sub>3</sub></th>
<td class="td-width">
<div>42 mm</div>
</td>
<td>Outside diameter</td>
</tr>
<tr>
<th scope="row">d<sub>4</sub></th>
<td class="td-width">
<div>26 mm</div>
</td>
<td>Inner diameter locating side face</td>
</tr>
<tr>
<th scope="row">J<sub>1</sub></th>
<td class="td-width">
<div>32.5 mm</div>
</td>
<td>Pitch diameter for pin-type face spanner</td>
</tr>
<tr>
<th scope="row">J<sub>2</sub></th>
<td class="td-width">
<div>11 mm</div>
</td>
<td>Distance between holes for pin-wrench and locating side face</td>
</tr>
<tr>
<th scope="row">N<sub>1</sub></th>
<td class="td-width">
<div>4.3 mm</div>
</td>
<td>Diameter holes for pin-type face spanner</td>
</tr>
<tr>
<th scope="row">N<sub>2</sub></th>
<td class="td-width">
<div>4 mm</div>
</td>
<td>Diameter holes for pin-wrench</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div class="content-block">
<div class="row">
<div class="col-md-8 full-row">
<h3 class="pb-4 pdf-title">CALCULATION DATA</h3>
<table class="table">
<tbody>
<tr>
<td class="td-width-2">
<div>130 kN</div>
</td>
<td>Axial static load carrying capacity</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div class="content-block">
<div class="row">
<div class="col-md-8 full-row">
<h3 class="pb-4 pdf-title">MASS</h3>
<table class="table">
<tbody>
<tr>
<td class="td-width-2">
<div>0.13 kg</div>
</td>
<td>Mass</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div class="content-block">
<div class="row">
<div class="col-md-8 full-row">
<h3 class="pb-4 pdf-title">MOUNTING INFORMATION</h3>
<table class="table">
<tbody>
<tr>
<td class="td-width-2">
<div>B 40-42</div>
</td>
<td>Associated spanner (Hook spanner in accordance with DIN 1810)</td>
</tr>
<tr>
<td class="td-width-2">
<div>M6</div>
</td>
<td>Grub (set) / Locking screw size</td>
</tr>
<tr>
<td class="td-width-2">
<div>8 N·m</div>
</td>
<td>Recommended tightening torque</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Công tắc áp lực dầu bôi trơn SKF VK5000-NEC</title>
		<link>https://congcusanxuat.vn/san-pham/cong-tac-ap-luc-dau-boi-tron-skf-vk5000-nec/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 06:19:20 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=12421</guid>

					<description><![CDATA[<a href="https://www.skf.com/group">Công tắc áp lực dầu bôi trơn SKF VK5000-NEC</a>]]></description>
										<content:encoded><![CDATA[<a href="https://www.skf.com/group">Công tắc áp lực dầu bôi trơn SKF VK5000-NEC</a>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mỡ động cơ SKF LGMT 2 (General purpose industrial and automotive NLGI 2 grease)</title>
		<link>https://congcusanxuat.vn/san-pham/mo-dong-co-skf-lgmt-2-general-purpose-industrial-and-automotive-nlgi-2-grease/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Thu, 02 Apr 2020 17:47:00 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=11245</guid>

					<description><![CDATA[Designation	 	LGMT 2/(pack size)
DIN 51825 code	 	K2K-30
NLGI consistency class	 	2
Thickener	 	Lithium
Colour	 	Red brown
Base oil type	 	Mineral
Operating temperature range	 	–30 to +120 °C (–20 to +250 °F)
Dropping point DIN ISO 2176	 	>180 °C (>355 °F)
Base oil viscosity
40 °C, mm²/s	110
100 °C, mm²/s	11
Penetration DIN ISO 2137:
60 strokes, 10–¹ mm	 265–295
100 000 strokes, 10–¹ mm	+50 max. (325 max.)
Mechanical stability
Roll stability, 50 hrs at 80 °C, 10–¹ mm	 +50 max.
V2F test	‘M’
Corrosion protection
Emcor: – standard ISO 11007	 0–0
Emcor: – water washout test	0–0
Emcor: – salt water test  (100% seawater)	0–1*
Water resistance	DIN 51 807/1, 3 hrs at 90 °C	 1 max.
Oil separation	DIN 51 817, 7 days at 40 °C, static, %	1–6
Lubrication ability	R2F, running test B at 120 °C	Pass
Copper corrosion
DIN 51 811	2 max. at 110 °C (230 °F)
Shelf life	 	5 years]]></description>
										<content:encoded><![CDATA[Designation	 	LGMT 2/(pack size)
DIN 51825 code	 	K2K-30
NLGI consistency class	 	2
Thickener	 	Lithium
Colour	 	Red brown
Base oil type	 	Mineral
Operating temperature range	 	–30 to +120 °C (–20 to +250 °F)
Dropping point DIN ISO 2176	 	>180 °C (>355 °F)
Base oil viscosity
40 °C, mm²/s	110
100 °C, mm²/s	11
Penetration DIN ISO 2137:
60 strokes, 10–¹ mm	 265–295
100 000 strokes, 10–¹ mm	+50 max. (325 max.)
Mechanical stability
Roll stability, 50 hrs at 80 °C, 10–¹ mm	 +50 max.
V2F test	‘M’
Corrosion protection
Emcor: – standard ISO 11007	 0–0
Emcor: – water washout test	0–0
Emcor: – salt water test  (100% seawater)	0–1*
Water resistance	DIN 51 807/1, 3 hrs at 90 °C	 1 max.
Oil separation	DIN 51 817, 7 days at 40 °C, static, %	1–6
Lubrication ability	R2F, running test B at 120 °C	Pass
Copper corrosion
DIN 51 811	2 max. at 110 °C (230 °F)
Shelf life	 	5 years]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bơm dầu bôi trơn SKF FLMF (Electrically operated vane pumps for use in oil circulation systems)</title>
		<link>https://congcusanxuat.vn/san-pham/bom-dau-boi-tron-skf-flmf-electrically-operated-vane-pumps-for-use-in-oil-circulation-systems/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 31 Mar 2020 05:36:38 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=10967</guid>

					<description><![CDATA[FLMF allows the pump to be flange-mounted on the reservoir (FLMF) both vertically and horizontally. When installed on the side (horizontally), the unit should be mounted above the maximum lubricant level. 
High suction capacity (3 m) 
Designed for 24/7 operation 
Delivers oil and air mixtures 
Fail safe running functions ]]></description>
										<content:encoded><![CDATA[FLMF allows the pump to be flange-mounted on the reservoir (FLMF) both vertically and horizontally. When installed on the side (horizontally), the unit should be mounted above the maximum lubricant level. 
High suction capacity (3 m) 
Designed for 24/7 operation 
Delivers oil and air mixtures 
Fail safe running functions ]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Bơm dầu SKF MKU (MKU gear pump unit)</title>
		<link>https://congcusanxuat.vn/san-pham/bom-dau-skf-mku-mku-gear-pump-unit/</link>
		
		<dc:creator><![CDATA[Pham Huyen]]></dc:creator>
		<pubDate>Tue, 31 Mar 2020 05:33:46 +0000</pubDate>
				<guid isPermaLink="false">http://congcusanxuat.vn/?post_type=product&#038;p=10965</guid>

					<description><![CDATA[Function principle	Electrically operated gear pump
Lubricant
MKU; MKL	mineral oil or synthetic oil, 20-1500 mm²/s
MKF	fluid grease NLGI 000 or 00
Number of lubricant outlets	1
Metering quantity	100; 200; 500 cm³/min	6; 12; 31 in³/min
Operating temperature	+10 to 40 °C	+50 to 104 °F
Operating pressure	max. 30 bar	435 psi
Capacity of the reservoir	2,0; 3,0 and 6,0 l	0.5, 0.8 and 1.6 gal
Material (reservoir)	plastic, metal
Connection outlet	G 1/4
Protection class	IP 54
Voltage	24 V DC
115 or 230 V AC; 50/60 Hz
Dimensions depending on reservoir
2 l; 0.5 gal plastic	204 × 130 × 298 mm	8 × 5.2 × 11.7 in
3 l; 0.8 gal plastic	286 × 132 × 298 mm	11.3 × 5.2 × 11.7 in
3 l; 0.8 gal metal	286 × 132 × 313 mm	11.3 × 5.2 × 12.3 in
6 l; 1,5 gal plastic	290 × 178 × 334 mm	11.4 × 7 × 13.2 in
Mounting position	vertical]]></description>
										<content:encoded><![CDATA[Function principle	Electrically operated gear pump
Lubricant
MKU; MKL	mineral oil or synthetic oil, 20-1500 mm²/s
MKF	fluid grease NLGI 000 or 00
Number of lubricant outlets	1
Metering quantity	100; 200; 500 cm³/min	6; 12; 31 in³/min
Operating temperature	+10 to 40 °C	+50 to 104 °F
Operating pressure	max. 30 bar	435 psi
Capacity of the reservoir	2,0; 3,0 and 6,0 l	0.5, 0.8 and 1.6 gal
Material (reservoir)	plastic, metal
Connection outlet	G 1/4
Protection class	IP 54
Voltage	24 V DC
115 or 230 V AC; 50/60 Hz
Dimensions depending on reservoir
2 l; 0.5 gal plastic	204 × 130 × 298 mm	8 × 5.2 × 11.7 in
3 l; 0.8 gal plastic	286 × 132 × 298 mm	11.3 × 5.2 × 11.7 in
3 l; 0.8 gal metal	286 × 132 × 313 mm	11.3 × 5.2 × 12.3 in
6 l; 1,5 gal plastic	290 × 178 × 334 mm	11.4 × 7 × 13.2 in
Mounting position	vertical]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
