Lưu lượng kế Aichi Tokei NW10-NTN

Danh mục:

Mô tả

Feature

・Built-in lithium batteries (No external power supply is required) ・Indications of both instantaneous flow-rate and integrating flow volume by only 1 flowmeter ・Revolving display unit (It can be fixed to a easy-to-read position) ・Simplified structure with the vane wheel type measuring principle ・Measurement of various liquids ・Reset function for indications of Integrating Flow Volume (Total) and Integrating Flow Volume (Trip) ・Value holding function for Instantaneous Flow-Rate indication ・Pulse output function (Option)

Model NW (Local display type) Model NW-P (With pulse output)

Enhanced basic functions, user friendliness and cost efficiency are the key points

ND series offers high accuracy measurement of not only cold and warm water but also pure water, chemical fluids, etc. It is light-weighted compact body and is compatible with various kinds of fluids with the carefully selected casing materials such as PP, ETFE, PPO, etc., and with the highly sensitive magnetic sensor of our own development. This series is therefore widely applicable for various flow measurements and its control and monitoring as well.

Flowsensor Applications

・To control of warm water temperature ・To constantly supply water and warm water ・To monitor coolant, etc. ・To proportionally inject chemical fluids ・To control pressure loss of filters

Specifications

Instantaneous flow-rate· Integrating flow volume flowmeter NW TypeNW05-NTNNW05-PTNNW05-TTNNW10-NTN
Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P TypeNW05-NTPNW05-PTPNW05-TTPNW10-NTP
Flow-rate range (m3/h)0.3 – 3L/min1.5 – 20L/min
AccuracyFlow-rate indication±2%RS±0.05L/min±2% RS±0.2L/min
Volume indication±2%RS (with the standard installation position)
Measurable fluidsVarious liquids (Please select with reference to the following major materials of the liquid-touching materials)
Max. Working Pressure1MPa (at the time of fluid temperature of 20°C)
Pressure DropNot more than 12kPa (At the time of 3L/min)Not more than 20kPa (At the time of 20L/min)
Fluid viscosity range0.5-1.5mPa・s
Fluid temperature range0±60°C
Ambient temperature range0±60°C 35-85%RH(Dew condensation must be avoided)
Output signal (for NW-P)Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFFresistance” Not less than 100kΩ (Remained voltage not morethan 1.5V in case of input current not more than 10mA)
Pulse unit (for NW-P)10mL/p1L/p
LCDFlow-rateSmallest Scale0.05L/min0.2L/min
Display digits00.00L/min000.0L/min
VolumeDisplay digits000000.00L0000000.0L
Power supplyBuilt-in lithium battery (Battery life 4 years. Not replaceable.)
Measurable fluidsRefer to “MEASURABLE FLUID AND PARTS MATERIALS”
StructureIP64 equivalent, Indoor installation
ConnectionR1/2
Meter WeightApprox. 280gApprox. 250g
Major materials of the liquid touching partsCasingDenatured PPOPPETFEDenatured PPO
Vane wheelPOMETFEPOM
PivotSUS304PAETFESUS304
O-ringNBRFKMNBR
MagnetSa-Co *1Ba-Fe
Instantaneous flow-rate· Integrating flow volume flowmeter NW TypeNW10-PTNNW10-TTNNW20-NTNNW20-PTN
Instantaneous flow-rate· Integrating flow volume flowmeter (with pulse output) NW-P TypeNW10-PTPNW10-TTPNW20-NTPNW20-PTP
Flow-rate range (m3/h)1.5-20L/min1.0-10L/min3.0-60L/min
AccuracyFlow-rate indication±2%RS±0.2L/min±2% RS±0.5L/min
Volume indication±2%RS (with the standard installation position)
Measurable fluidsVarious liquids (Please select with reference to the following major materials of the liquid-touching materials)
Max. Working Pressure1MPa (at the time of fluid temperature of 20°C)
Pressure DropNot more than 20kPa (At the time of 20L/min)Not more than 15kPa (At the time of 10L/min)Not more than 60kPa (At the time of 60L/min)
Fluid viscosity range0.5-1.5mPa·s
Fluid temperature range0±60°C
Ambient temperature range0±60°C 35-85%RH(Dew condensation must be avoided)
Output signal (for NW-P)Open drain output (Equivalent to open collector) Pulse width: Not less than 5ms Max. rating voltage: 30 VDC Output capacity: “ON resistance” Not more than 150Ω, “OFF resistance” Not less than 100kΩ (Remained voltage not more than 1.5V in case of input current not more than 10mA)
Pulse unit (for NW-P)1L/p
LCDFlow-rateSmallest Scale0.2L/min0.5L/min
Display digits000.0L/min
VolumeDisplay digits0000000.0L
Power supplyBuilt-in lithium battery (Battery life 4 years. Not replaceable.)
Measurable fluidsRefer to “MEASURABLE FLUID AND PARTS MATERIALS”
StructureIP64 equivalent, Indoor installation
ConnectionR1/2R3/4
Meter WeightApprox. 250gApprox. 500g
Major materials of the liquid touching partsCasingPPETFEDenatured PPOPP
Vane wheelPOMETFEPOM
PivotSUS304ETFESUS304
O-ringFKMNBRFKM
MagnetBa-FeSa-Co *1Ba-Fe

Any installation position other than the standard installation position is not available for NW05-TTN, NW05-TTP, NW10-TTN, and NW10-TTP. *1: The magnet does not touch liquid.

Dimensions

ModeNW05NW10NW20
A(mm)8080110
B(mm)8787105.5
C(mm)525274
D(mm)111116
E(mm)252535.5

nw_glaf

Standard installation position

The standard installation position is that the display is facing upwards. * The display is able to be revolved.

nw_position

Materials -Abbreviations

Denatured PPODenatured Polyphenylene oxide
PPPolypropylene
ETFEEthylene-tetrafiuoro ethylene
POMPolyacetal or Polyoxymethylene
SUS304Stainless steel 304
PAPolyamide
NBRAcrylonitrile-Butadiene Rubber
FKMFluoro Rubber
Sa-CoSamarium-Cobalt
Ba-FeBarium-ferrite

Handling Instructions

Observe the following handling instructions and precautions to obtain maximum performance of the Flowsensor / Flowmeter.

CAUTIONS IN MOUNTING

1. The flowing direction of the fluid, when mounting, must be matched to the arrow mark on the case that indicates the direction of flow.

2. A straight pipe with uniform inner diameter must be connected to the inlet. Accuracy is adversely affected if the pipe is bent or the inner diameter is uneven.

3. The inner diameter of the inlet pipe must be greater than the nozzle diameter of the Flowsensor / Flowmeter.

TypeInner D, of inlet pipeLength of straight pipe at inlet
ND05,NW055.5 mm or greaterGreater than 50 mm from the end of the Flowsensor / Flowmeter
ND10,NW1010.5 mm or greaterGreater than 100 mm from the end of the Flowsensor / Flowmeter
ND20,NW2015.5 mm or greater

4. If pulsation occurs in the flow of the fluid, measurement accuracy is adversely affected. When a pump is used to circulate the fluid, an accumulator must be provided to remove the pulsation.

5. Be careful not to apply excessive stress on the Flowsensor / Flowmeter during installation.

6. Make sure to provide thermal insulator at places subject to freezing in winter. When leakage occurs due to half frozen fluid, accuracy is adversely affected.

7. Do not expose/install the Flowsensor / Flowmeter under direct sunshine.

8. The measuring range, operating pressure and operating temperature are indicated on the plate on the side of the Flowsensor / Flowmeter. Observe these conditions for optimum performance of the Flowsensor / Flowmeter.

9. Avoid locating the Flowsensor / Flowmeter at places subject to excessive pressure and stress such as water hammer by operating components.

10. When air enters the Flowsensor / Flowmeter, measurement accuracy is influenced. Always operate the Flowsensor / Flowmeter chamber full of fluid. To maintain high accuracy, avoid mixture of air to the fluid.

11. Avoid placing a strong magnetic material or magnetic field near the Flowsensor / Flowmeter.

12. Installation position is flexible except those shown in figures on the upper right. However, it is recommended to install the Flowsensor / Flowmeter at the standard position whenever possible. For types ND 05-TATAAA, ND10-TATAAA, NW05-TTN, NW10-TTN, installation must be at standard positions.

Standard mounting position

sample2

CONNECTION (WIRING)

sample3

Measurable fluids and parts materials

MEASURABLE FLUIDS

1.Fluid which done not corrode materials that contact the fluid. 2.Viscosity of the fluid to be measured is between 0.5 and 1.5cp. 3.No slurry is contained. 4.Particles attracted by magnetic power such as iron, is contained in the fluid. (All of the above 1-4 must be satisfied.)

LIST OF MATERIALS THAT CONTACT FLUIDS DIRECTLY

The table below shows components and materials of the standard type Flowsensor / Flowmeter used in portions that come into direct contact with the fluid.

Parts nameModel
ND05-PATAAC NW05-PTN NW05-PTPND05-NATAAC NW05-NTN NW05-NTPND05-TATAAA NW05-TTN NW05-TTP ND10-TATAAA NW10-TTN NW10-TTPND10-PATAAA NW10-PTN NW10-PTPND20-PATAAA NW20-PTN NW20-PTPND10-NATAAA NW10-NTN NW10-NTP ND20-NATAAA NW20-NTN NW20-NTP
Lower casing Upper casing RegulatorPPDenatured PPOETFEPPPPDenatured PPO
Vane-wheelPOMPOMPOMPOMPOM
PivotPASUS304PASUS304SUS304
O-ringFKMNBRFKMFKMFKMNBR
MagnetSamarium cobalt (No contact with fluid)Samarium cobalt (No contact with fluid)Samarium cobalt (No contact with fluid)Ba-FeBa-FeBa-Fe
Measurable fluidWater, Chemical fluid (Weak corrosion resistance)Water, Warm WaterChemical fluidWater, Chemical Fluid (Weak corrosion resistance)Water, Warm Water

Material Code

・Ba-Fe: Barium-Ferrite ・ETFE: Ethylene-tetrafluoro ethylene ・FKM: Fluoro Rubber ・NBR: Acrylonitrile-butadiene rubber ・PA: Polyamide ・POM: Polyacetal or Polyoxymethylene ・PP: Polypropylene ・PPO: Polyphenylene oxide ・SUS304: Stainless steel